Vibrational spectroscopic analysis of body fluids

avoiding molecular contamination using centrifugal filtration

Franck Bonnier, Matthew J. Baker, Hugh J. Byrne

Research output: Contribution to journalArticle

14 Citations (Scopus)

Abstract

The use of centrifugal filtration for protein purification and concentration represents an important improvement for the application of vibrational spectroscopy to analysis of bodily fluids based on protein fractions with specific molecular weight. Vibrational spectroscopic techniques are highly specific and can potentially detect small variations in the protein content indicating the presence of different diseases, and are therefore usable as markers for early diagnostics. However, due to the high sensitivity of the techniques, it is essential to verify that no molecular contamination occurs during the preparation of the samples. Concentration of the blood serum using commercially available centrifugal filters has been shown to result in an improvement in the spectral intensity and quality. However, the presence of contaminant features, identified as deriving from glycerine, can be found in the data collected after use of the centrifugal filters. It is demonstrated in the present work that careful washing of the filters is required before the analysis of body fluids based on concentrated samples. The demonstrated protocols for spectroscopic measurement of human serum are applicable to a range of bodily fluids and should accelerate potential clinical applications.

Original languageEnglish
Pages (from-to)5155-5160
Number of pages6
JournalAnalytical Methods
Volume6
Issue number14
Early online date15 May 2014
DOIs
Publication statusPublished - 21 Jul 2014

Fingerprint

Spectroscopic analysis
Body fluids
Contamination
Proteins
Vibrational spectroscopy
Fluids
Glycerol
Washing
Purification
Blood
Molecular weight
Impurities

Keywords

  • protein purification
  • vibrational spectroscopy
  • body fluids

Cite this

@article{0553f0ebde844405a28ee42d8b0b572c,
title = "Vibrational spectroscopic analysis of body fluids: avoiding molecular contamination using centrifugal filtration",
abstract = "The use of centrifugal filtration for protein purification and concentration represents an important improvement for the application of vibrational spectroscopy to analysis of bodily fluids based on protein fractions with specific molecular weight. Vibrational spectroscopic techniques are highly specific and can potentially detect small variations in the protein content indicating the presence of different diseases, and are therefore usable as markers for early diagnostics. However, due to the high sensitivity of the techniques, it is essential to verify that no molecular contamination occurs during the preparation of the samples. Concentration of the blood serum using commercially available centrifugal filters has been shown to result in an improvement in the spectral intensity and quality. However, the presence of contaminant features, identified as deriving from glycerine, can be found in the data collected after use of the centrifugal filters. It is demonstrated in the present work that careful washing of the filters is required before the analysis of body fluids based on concentrated samples. The demonstrated protocols for spectroscopic measurement of human serum are applicable to a range of bodily fluids and should accelerate potential clinical applications.",
keywords = "protein purification, vibrational spectroscopy, body fluids",
author = "Franck Bonnier and Baker, {Matthew J.} and Byrne, {Hugh J.}",
year = "2014",
month = "7",
day = "21",
doi = "10.1039/c4ay00891j",
language = "English",
volume = "6",
pages = "5155--5160",
journal = "Analytical Methods",
issn = "1759-9660",
number = "14",

}

Vibrational spectroscopic analysis of body fluids : avoiding molecular contamination using centrifugal filtration. / Bonnier, Franck; Baker, Matthew J.; Byrne, Hugh J.

In: Analytical Methods, Vol. 6, No. 14, 21.07.2014, p. 5155-5160.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Vibrational spectroscopic analysis of body fluids

T2 - avoiding molecular contamination using centrifugal filtration

AU - Bonnier, Franck

AU - Baker, Matthew J.

AU - Byrne, Hugh J.

PY - 2014/7/21

Y1 - 2014/7/21

N2 - The use of centrifugal filtration for protein purification and concentration represents an important improvement for the application of vibrational spectroscopy to analysis of bodily fluids based on protein fractions with specific molecular weight. Vibrational spectroscopic techniques are highly specific and can potentially detect small variations in the protein content indicating the presence of different diseases, and are therefore usable as markers for early diagnostics. However, due to the high sensitivity of the techniques, it is essential to verify that no molecular contamination occurs during the preparation of the samples. Concentration of the blood serum using commercially available centrifugal filters has been shown to result in an improvement in the spectral intensity and quality. However, the presence of contaminant features, identified as deriving from glycerine, can be found in the data collected after use of the centrifugal filters. It is demonstrated in the present work that careful washing of the filters is required before the analysis of body fluids based on concentrated samples. The demonstrated protocols for spectroscopic measurement of human serum are applicable to a range of bodily fluids and should accelerate potential clinical applications.

AB - The use of centrifugal filtration for protein purification and concentration represents an important improvement for the application of vibrational spectroscopy to analysis of bodily fluids based on protein fractions with specific molecular weight. Vibrational spectroscopic techniques are highly specific and can potentially detect small variations in the protein content indicating the presence of different diseases, and are therefore usable as markers for early diagnostics. However, due to the high sensitivity of the techniques, it is essential to verify that no molecular contamination occurs during the preparation of the samples. Concentration of the blood serum using commercially available centrifugal filters has been shown to result in an improvement in the spectral intensity and quality. However, the presence of contaminant features, identified as deriving from glycerine, can be found in the data collected after use of the centrifugal filters. It is demonstrated in the present work that careful washing of the filters is required before the analysis of body fluids based on concentrated samples. The demonstrated protocols for spectroscopic measurement of human serum are applicable to a range of bodily fluids and should accelerate potential clinical applications.

KW - protein purification

KW - vibrational spectroscopy

KW - body fluids

UR - http://www.scopus.com/inward/record.url?scp=84903624886&partnerID=8YFLogxK

U2 - 10.1039/c4ay00891j

DO - 10.1039/c4ay00891j

M3 - Article

VL - 6

SP - 5155

EP - 5160

JO - Analytical Methods

JF - Analytical Methods

SN - 1759-9660

IS - 14

ER -