Total knee arthroplasty using a cemented single-radius, condylar-stabilized design performed without posterior cruciate ligament sacrifice: excellent survival and functional outcomes demonstrated at ten-year follow-up of 536 cases

Andrew Hall, R Cullinan, Glory Alozie, Swati Chopra, L Greig, Jon Clarke, Phil Riches, P Walmesley, Nick Ohly, Nicholas Holloway

Research output: Contribution to journalArticlepeer-review

Abstract

Aims Total knee arthroplasty (TKA) with a highly congruent condylar-stabilized (CS) articulation may be advantageous due to increased stability versus cruciate-retaining (CR) designs, while mitigating the limitations of a posterior-stabilized construct. The aim was to assess ten-year implant survival and functional outcomes of a cemented single-radius TKA with a CS insert, performed without posterior cruciate ligament sacrifice. Methods This retrospective cohort study included consecutive patients undergoing TKA at a specialist centre in the UK between November 2010 and December 2012. Data were collected using a bespoke electronic database and cross-referenced with national arthroplasty audit data, with variables including: preoperative characteristics, intraoperative factors, complications, and mortality status. Patient-reported outcome measures (PROMs) were collected by a specialist research team at ten years post-surgery. There were 536 TKAs, of which 308/536 (57.5%) were in female patients. The mean age was 69.0 years (95% CI 45.0 to 88.0), the mean BMI was 32.2 kg/m 2 (95% CI 18.9 to 50.2), and 387/536 (72.2%) survived to ten years. There were four revisions (0.7%): two deep infections (requiring debridement and implant retention), one aseptic loosening, and one haemosiderosis. Results Kaplan-Meier analysis demonstrated no difference in implant survival according to sex, age, or obesity status. Ten-year PROMs were available for 196/387 (50.6%) surviving patients and were excellent: mean Oxford Knee Score 34.4 (95% CI 32.7 to 36.1); mean Forgotten Joint Score (FJS) 51.2 (95% CI 16.1 to 86.3); mean EuroQol five-dimension five-level questionnaire score 69.9 (95% CI 46.8 to 93.0); 141/196 (71.9%) achieved the 22-point FJS patient-acceptable symptom state (PASS); and 156/196 (79.6%) were “very satisfied or satisfied”. Conclusion This is the only large study reporting ten-year implant survival and functional outcomes of TKA using a cemented single-radius design and with a CS tibial bearing construct. The findings of excellent implant survival, safety, and functional outcomes indicate that this combination is a safe and effective option in routine TKA. Further investigation of this single-radius design TKA with CS tibial bearings with well-matched patient study groups will allow further insight into the performance of these implants.

Original languageEnglish
Pages (from-to)808-816
Number of pages9
JournalThe Bone & Joint Journal
Volume106-B
Issue number8
DOIs
Publication statusPublished - 1 Aug 2024

Keywords

  • Total knee arthroplasty
  • implant survival
  • functional outcomes

Fingerprint

Dive into the research topics of 'Total knee arthroplasty using a cemented single-radius, condylar-stabilized design performed without posterior cruciate ligament sacrifice: excellent survival and functional outcomes demonstrated at ten-year follow-up of 536 cases'. Together they form a unique fingerprint.

Cite this