Tissue surface as the reference arm in fourier domain optical coherence tomography

Nikola Krstajić, Praveen C. Ashok, Wilson Sibbett, Christian T. A. Brown, Kishan Dholakia, Mario E. Giardini

Research output: Chapter in Book/Report/Conference proceedingConference contribution book

Abstract

We present a method to use the tissue surface as reference in common-path Fourier domain optical coherence tomography. This allows a very long sample arm. The sensitivity is 94dB for 50 μs CCD integration time.
LanguageEnglish
Title of host publicationBiomedical Optics
Place of PublicationWashington
PublisherOptical Society of America
ISBN (Print)9781557529428
DOIs
Publication statusPublished - 28 Apr 2012
EventBiomedical Optics 2012 - Miami, United States
Duration: 28 Apr 20122 May 2012
http://www.osa.org/osaorg/media/osa.media/Meetings/Archives/2012/BIOMED-2012-Archive.pdf

Publication series

NameOSA Technical Digest

Conference

ConferenceBiomedical Optics 2012
CountryUnited States
CityMiami
Period28/04/122/05/12
Internet address

Fingerprint

Optical tomography
Charge coupled devices
Tissue

Keywords

  • optical coherence tomogrpahy
  • fourier domain
  • reference arm
  • tissue surface

Cite this

Krstajić, N., Ashok, P. C., Sibbett, W., Brown, C. T. A., Dholakia, K., & Giardini, M. E. (2012). Tissue surface as the reference arm in fourier domain optical coherence tomography. In Biomedical Optics [BTu3A.80] (OSA Technical Digest). Washington: Optical Society of America. https://doi.org/10.1364/BIOMED.2012.BTu3A.80
Krstajić, Nikola ; Ashok, Praveen C. ; Sibbett, Wilson ; Brown, Christian T. A. ; Dholakia, Kishan ; Giardini, Mario E. / Tissue surface as the reference arm in fourier domain optical coherence tomography. Biomedical Optics. Washington : Optical Society of America, 2012. (OSA Technical Digest).
@inproceedings{744a5d7765564ed5b9471e4ff572690f,
title = "Tissue surface as the reference arm in fourier domain optical coherence tomography",
abstract = "We present a method to use the tissue surface as reference in common-path Fourier domain optical coherence tomography. This allows a very long sample arm. The sensitivity is 94dB for 50 μs CCD integration time.",
keywords = "optical coherence tomogrpahy, fourier domain, reference arm, tissue surface",
author = "Nikola Krstajić and Ashok, {Praveen C.} and Wilson Sibbett and Brown, {Christian T. A.} and Kishan Dholakia and Giardini, {Mario E.}",
year = "2012",
month = "4",
day = "28",
doi = "10.1364/BIOMED.2012.BTu3A.80",
language = "English",
isbn = "9781557529428",
series = "OSA Technical Digest",
publisher = "Optical Society of America",
booktitle = "Biomedical Optics",

}

Krstajić, N, Ashok, PC, Sibbett, W, Brown, CTA, Dholakia, K & Giardini, ME 2012, Tissue surface as the reference arm in fourier domain optical coherence tomography. in Biomedical Optics., BTu3A.80, OSA Technical Digest, Optical Society of America, Washington, Biomedical Optics 2012, Miami, United States, 28/04/12. https://doi.org/10.1364/BIOMED.2012.BTu3A.80

Tissue surface as the reference arm in fourier domain optical coherence tomography. / Krstajić, Nikola; Ashok, Praveen C.; Sibbett, Wilson; Brown, Christian T. A.; Dholakia, Kishan; Giardini, Mario E.

Biomedical Optics. Washington : Optical Society of America, 2012. BTu3A.80 (OSA Technical Digest).

Research output: Chapter in Book/Report/Conference proceedingConference contribution book

TY - GEN

T1 - Tissue surface as the reference arm in fourier domain optical coherence tomography

AU - Krstajić, Nikola

AU - Ashok, Praveen C.

AU - Sibbett, Wilson

AU - Brown, Christian T. A.

AU - Dholakia, Kishan

AU - Giardini, Mario E.

PY - 2012/4/28

Y1 - 2012/4/28

N2 - We present a method to use the tissue surface as reference in common-path Fourier domain optical coherence tomography. This allows a very long sample arm. The sensitivity is 94dB for 50 μs CCD integration time.

AB - We present a method to use the tissue surface as reference in common-path Fourier domain optical coherence tomography. This allows a very long sample arm. The sensitivity is 94dB for 50 μs CCD integration time.

KW - optical coherence tomogrpahy

KW - fourier domain

KW - reference arm

KW - tissue surface

UR - http://www.osa.org/osaorg/media/osa.media/Meetings/Archives/2012/BIOMED-2012-Archive.pdf

U2 - 10.1364/BIOMED.2012.BTu3A.80

DO - 10.1364/BIOMED.2012.BTu3A.80

M3 - Conference contribution book

SN - 9781557529428

T3 - OSA Technical Digest

BT - Biomedical Optics

PB - Optical Society of America

CY - Washington

ER -

Krstajić N, Ashok PC, Sibbett W, Brown CTA, Dholakia K, Giardini ME. Tissue surface as the reference arm in fourier domain optical coherence tomography. In Biomedical Optics. Washington: Optical Society of America. 2012. BTu3A.80. (OSA Technical Digest). https://doi.org/10.1364/BIOMED.2012.BTu3A.80