The influence of pulse duration on the inactivation of bacteria using monopolar and bipolar profile pulsed electric fields

J.R. Beveridge, S.J. MacGregor, J.G. Anderson, R.A. Fouracre

Research output: Contribution to journalArticle

31 Citations (Scopus)

Abstract

In recent years, a number of new applications have emerged where pulsed power is being used in the treatment of waste and effluent, foodstuffs, and beverages. One of these emerging applications is pulsed electric field (PEF) inactivation of microorganisms in liquid media. There are several ways in which PEF can be applied, including oscillatory, double exponential, and square wave pulses. Of these, the square-wave pulse is considered to be the most energy-efficient form of PEF delivery. It has been reported that the bipolar square-wave pulse, involving polarity reversal half way through the pulse, provides superior inactivation when compared to the monopolar pulse. However, results from the authors have shown that this is not always the case and that monopolar PEF is at least as effective for bacterial inactivation under the conditions investigated (Beveridge, et. al., 2004). Further results are presented here on the effect of changing the pulse duration of the monopolar and bipolar pulse, using total pulse durations of 1, 2, 3, and 4$mu$s. These results, obtained from an improved system, demonstrate how the relative effectiveness of inactivation is a function of the pulse duration. When inactivation is plotted against energy delivered, they show the superiority of monopolar over bipolar pulses for 1- and 2-$mu$s pulse profiles. For a pulse duration of around 3$mu$s, there is no significant difference, and with still longer pulses, bipolar pulses appear to be superior to monopolar. It is postulated that electric-field-induced orientation may, in part, be responsible for this effect. These comparative experiments are conducted with complete control of the fluid temperature, which is maintained below 30$^circ$C.
LanguageEnglish
Pages1287-1293
Number of pages6
JournalIEEE Transactions on Plasma Science
Volume33
Issue number4
DOIs
Publication statusPublished - 2005

Fingerprint

deactivation
bacteria
pulse duration
electric fields
profiles
pulses
square waves
beverages
effluents
microorganisms
emerging
delivery
polarity
energy
fluids
liquids

Keywords

  • biology
  • biological techniques
  • radiation
  • cells
  • microorganisms
  • bacteria
  • plasma science
  • pulsed power
  • pulsed electric field
  • electronic sterilization
  • microbial inactivation

Cite this

@article{a0d064829b4446dabd4dbca4cf42af5c,
title = "The influence of pulse duration on the inactivation of bacteria using monopolar and bipolar profile pulsed electric fields",
abstract = "In recent years, a number of new applications have emerged where pulsed power is being used in the treatment of waste and effluent, foodstuffs, and beverages. One of these emerging applications is pulsed electric field (PEF) inactivation of microorganisms in liquid media. There are several ways in which PEF can be applied, including oscillatory, double exponential, and square wave pulses. Of these, the square-wave pulse is considered to be the most energy-efficient form of PEF delivery. It has been reported that the bipolar square-wave pulse, involving polarity reversal half way through the pulse, provides superior inactivation when compared to the monopolar pulse. However, results from the authors have shown that this is not always the case and that monopolar PEF is at least as effective for bacterial inactivation under the conditions investigated (Beveridge, et. al., 2004). Further results are presented here on the effect of changing the pulse duration of the monopolar and bipolar pulse, using total pulse durations of 1, 2, 3, and 4$mu$s. These results, obtained from an improved system, demonstrate how the relative effectiveness of inactivation is a function of the pulse duration. When inactivation is plotted against energy delivered, they show the superiority of monopolar over bipolar pulses for 1- and 2-$mu$s pulse profiles. For a pulse duration of around 3$mu$s, there is no significant difference, and with still longer pulses, bipolar pulses appear to be superior to monopolar. It is postulated that electric-field-induced orientation may, in part, be responsible for this effect. These comparative experiments are conducted with complete control of the fluid temperature, which is maintained below 30$^circ$C.",
keywords = "biology, biological techniques, radiation, cells, microorganisms, bacteria, plasma science, pulsed power, pulsed electric field, electronic sterilization, microbial inactivation",
author = "J.R. Beveridge and S.J. MacGregor and J.G. Anderson and R.A. Fouracre",
year = "2005",
doi = "10.1109/TPS.2005.852345",
language = "English",
volume = "33",
pages = "1287--1293",
journal = "IEEE Transactions on Plasma Science",
issn = "0093-3813",
number = "4",

}

The influence of pulse duration on the inactivation of bacteria using monopolar and bipolar profile pulsed electric fields. / Beveridge, J.R.; MacGregor, S.J.; Anderson, J.G.; Fouracre, R.A.

In: IEEE Transactions on Plasma Science, Vol. 33, No. 4, 2005, p. 1287-1293.

Research output: Contribution to journalArticle

TY - JOUR

T1 - The influence of pulse duration on the inactivation of bacteria using monopolar and bipolar profile pulsed electric fields

AU - Beveridge, J.R.

AU - MacGregor, S.J.

AU - Anderson, J.G.

AU - Fouracre, R.A.

PY - 2005

Y1 - 2005

N2 - In recent years, a number of new applications have emerged where pulsed power is being used in the treatment of waste and effluent, foodstuffs, and beverages. One of these emerging applications is pulsed electric field (PEF) inactivation of microorganisms in liquid media. There are several ways in which PEF can be applied, including oscillatory, double exponential, and square wave pulses. Of these, the square-wave pulse is considered to be the most energy-efficient form of PEF delivery. It has been reported that the bipolar square-wave pulse, involving polarity reversal half way through the pulse, provides superior inactivation when compared to the monopolar pulse. However, results from the authors have shown that this is not always the case and that monopolar PEF is at least as effective for bacterial inactivation under the conditions investigated (Beveridge, et. al., 2004). Further results are presented here on the effect of changing the pulse duration of the monopolar and bipolar pulse, using total pulse durations of 1, 2, 3, and 4$mu$s. These results, obtained from an improved system, demonstrate how the relative effectiveness of inactivation is a function of the pulse duration. When inactivation is plotted against energy delivered, they show the superiority of monopolar over bipolar pulses for 1- and 2-$mu$s pulse profiles. For a pulse duration of around 3$mu$s, there is no significant difference, and with still longer pulses, bipolar pulses appear to be superior to monopolar. It is postulated that electric-field-induced orientation may, in part, be responsible for this effect. These comparative experiments are conducted with complete control of the fluid temperature, which is maintained below 30$^circ$C.

AB - In recent years, a number of new applications have emerged where pulsed power is being used in the treatment of waste and effluent, foodstuffs, and beverages. One of these emerging applications is pulsed electric field (PEF) inactivation of microorganisms in liquid media. There are several ways in which PEF can be applied, including oscillatory, double exponential, and square wave pulses. Of these, the square-wave pulse is considered to be the most energy-efficient form of PEF delivery. It has been reported that the bipolar square-wave pulse, involving polarity reversal half way through the pulse, provides superior inactivation when compared to the monopolar pulse. However, results from the authors have shown that this is not always the case and that monopolar PEF is at least as effective for bacterial inactivation under the conditions investigated (Beveridge, et. al., 2004). Further results are presented here on the effect of changing the pulse duration of the monopolar and bipolar pulse, using total pulse durations of 1, 2, 3, and 4$mu$s. These results, obtained from an improved system, demonstrate how the relative effectiveness of inactivation is a function of the pulse duration. When inactivation is plotted against energy delivered, they show the superiority of monopolar over bipolar pulses for 1- and 2-$mu$s pulse profiles. For a pulse duration of around 3$mu$s, there is no significant difference, and with still longer pulses, bipolar pulses appear to be superior to monopolar. It is postulated that electric-field-induced orientation may, in part, be responsible for this effect. These comparative experiments are conducted with complete control of the fluid temperature, which is maintained below 30$^circ$C.

KW - biology

KW - biological techniques

KW - radiation

KW - cells

KW - microorganisms

KW - bacteria

KW - plasma science

KW - pulsed power

KW - pulsed electric field

KW - electronic sterilization

KW - microbial inactivation

UR - http://dx.doi.org/10.1109/TPS.2005.852345

U2 - 10.1109/TPS.2005.852345

DO - 10.1109/TPS.2005.852345

M3 - Article

VL - 33

SP - 1287

EP - 1293

JO - IEEE Transactions on Plasma Science

T2 - IEEE Transactions on Plasma Science

JF - IEEE Transactions on Plasma Science

SN - 0093-3813

IS - 4

ER -