Abstract
Epidemiological evidence suggests that the presence of biocontaminants within buildings, such as dust mites and microfungi, can have a detrimental effect on the well-being of occupants. As a result, considerable attention has been focussed over the past few years on the measurement of the environmental conditions within biocontaminant microenvironments, which may have a spatial scale of only a few millimeters. Until recently, the major restriction in this regard was the lack of a humidity sensor with the necessary spatial resolution. The recent availability of microchip-based sensors has removed this restriction. This paper reports on the development of a humidity measurement system for microenvironment investigations. It also describes the validation of the system through a series of laboratory experiments and the novel application of a dynamic heat and mass simulation model as a suitable means of interpreting measured data.
| Original language | English |
|---|---|
| Pages (from-to) | 565-574 |
| Number of pages | 9 |
| Journal | Measurement |
| Volume | 39 |
| Issue number | 6 |
| DOIs | |
| Publication status | Published - Jan 2006 |
Keywords
- humidity
- humidity sensor
- biocontaminants
- microenvironments
Fingerprint
Dive into the research topics of 'The development of instrumentation for the measurement of relative humidity within building microenvironments'. Together they form a unique fingerprint.Cite this