The Clinical Biomechanics Award 1988 Flexible goniometer computer system for the assessment of hip function

Research output: Contribution to journalArticle

27 Citations (Scopus)

Abstract

A new computer-based system has been developed to assess function in a clinical environment. Flexible electrogoniometers were used to record the motion of both hips and both knees in total hip replacement patients. Foot switches and instrumented walking aids were also incorporated, together with a fixed length timing facility for the derivation of walking velocity, stride length and cadence. The data can be presented on the computer screen immediately following the walking test in the form of angle/time or angle/angle graphs. This facility enables clinicians to study asymmetry and other abnormalities during the clinic session. A summary version of the data can thereafter be generated and included in the patient's notes. A total of 65 patients have been assessed prior to hip replacement and at 2, 6 and 12 months post-operatively. Following surgery, the patients exhibited significant improvments in range of motion, gait velocity and cadence but at 12 months post-operatively their functional performance was restricted compared to data collected for the normal subjects
Original languageEnglish
Pages (from-to)68-72
Number of pages5
JournalClinical Biomechanics
Volume4
Issue number2
DOIs
Publication statusPublished - May 1989

Fingerprint

Computer Systems
Biomechanical Phenomena
Hip
Walking
Hip Replacement Arthroplasties
Articular Range of Motion
Gait
Foot
Knee

Keywords

  • hip
  • gait
  • electrogoniometer
  • assessment
  • function
  • computer
  • prosthesis

Cite this

@article{912f199b41f649f683fed5f0e614f5aa,
title = "The Clinical Biomechanics Award 1988 Flexible goniometer computer system for the assessment of hip function",
abstract = "A new computer-based system has been developed to assess function in a clinical environment. Flexible electrogoniometers were used to record the motion of both hips and both knees in total hip replacement patients. Foot switches and instrumented walking aids were also incorporated, together with a fixed length timing facility for the derivation of walking velocity, stride length and cadence. The data can be presented on the computer screen immediately following the walking test in the form of angle/time or angle/angle graphs. This facility enables clinicians to study asymmetry and other abnormalities during the clinic session. A summary version of the data can thereafter be generated and included in the patient's notes. A total of 65 patients have been assessed prior to hip replacement and at 2, 6 and 12 months post-operatively. Following surgery, the patients exhibited significant improvments in range of motion, gait velocity and cadence but at 12 months post-operatively their functional performance was restricted compared to data collected for the normal subjects",
keywords = "hip, gait, electrogoniometer, assessment, function, computer, prosthesis",
author = "Philip Rowe and Alexander Nicol and Kelly, {I G}",
year = "1989",
month = "5",
doi = "10.1016/0268-0033(89)90041-7",
language = "English",
volume = "4",
pages = "68--72",
journal = "Clinical Biomechanics",
issn = "0268-0033",
number = "2",

}

The Clinical Biomechanics Award 1988 Flexible goniometer computer system for the assessment of hip function. / Rowe, Philip; Nicol, Alexander; Kelly, I G.

In: Clinical Biomechanics, Vol. 4, No. 2, 05.1989, p. 68-72.

Research output: Contribution to journalArticle

TY - JOUR

T1 - The Clinical Biomechanics Award 1988 Flexible goniometer computer system for the assessment of hip function

AU - Rowe, Philip

AU - Nicol, Alexander

AU - Kelly, I G

PY - 1989/5

Y1 - 1989/5

N2 - A new computer-based system has been developed to assess function in a clinical environment. Flexible electrogoniometers were used to record the motion of both hips and both knees in total hip replacement patients. Foot switches and instrumented walking aids were also incorporated, together with a fixed length timing facility for the derivation of walking velocity, stride length and cadence. The data can be presented on the computer screen immediately following the walking test in the form of angle/time or angle/angle graphs. This facility enables clinicians to study asymmetry and other abnormalities during the clinic session. A summary version of the data can thereafter be generated and included in the patient's notes. A total of 65 patients have been assessed prior to hip replacement and at 2, 6 and 12 months post-operatively. Following surgery, the patients exhibited significant improvments in range of motion, gait velocity and cadence but at 12 months post-operatively their functional performance was restricted compared to data collected for the normal subjects

AB - A new computer-based system has been developed to assess function in a clinical environment. Flexible electrogoniometers were used to record the motion of both hips and both knees in total hip replacement patients. Foot switches and instrumented walking aids were also incorporated, together with a fixed length timing facility for the derivation of walking velocity, stride length and cadence. The data can be presented on the computer screen immediately following the walking test in the form of angle/time or angle/angle graphs. This facility enables clinicians to study asymmetry and other abnormalities during the clinic session. A summary version of the data can thereafter be generated and included in the patient's notes. A total of 65 patients have been assessed prior to hip replacement and at 2, 6 and 12 months post-operatively. Following surgery, the patients exhibited significant improvments in range of motion, gait velocity and cadence but at 12 months post-operatively their functional performance was restricted compared to data collected for the normal subjects

KW - hip

KW - gait

KW - electrogoniometer

KW - assessment

KW - function

KW - computer

KW - prosthesis

U2 - 10.1016/0268-0033(89)90041-7

DO - 10.1016/0268-0033(89)90041-7

M3 - Article

VL - 4

SP - 68

EP - 72

JO - Clinical Biomechanics

JF - Clinical Biomechanics

SN - 0268-0033

IS - 2

ER -