Single sensor high-temperature superconducting axial gradiometer with thick film pick-up loops

S. Haining, E.J. Romans, C.M. Pegrum, G.B. Donaldson, L. Hao, J.C. Macfarlane

Research output: Contribution to journalArticlepeer-review

1 Citation (Scopus)

Abstract

A high-temperature superconducting first-order axial gradiometer with thick film YBa2Cu3O7-delta pick-up loops inductively coupled to a thin film YBa2Cu3O7-delta superconducting quantum interference device magnetometer has been designed, fabricated and characterized. The gradiometer has a baseline of 79 mm, an estimated intrinsic system balance of 1:480 for uniform axial magnetic fields and an estimated axial magnetic field gradient sensitivity of 70 fT/(cm root Hz) at 1 kHz, in magnetic shielding.

Original languageEnglish
Pages (from-to)769-772
Number of pages4
JournalIEEE Transactions on Applied Superconductivity
Volume15
Issue number2
DOIs
Publication statusPublished - Jun 2005

Keywords

  • SQUID gradiometers
  • SQUIDs
  • superconducting devices
  • performance
  • design

Fingerprint

Dive into the research topics of 'Single sensor high-temperature superconducting axial gradiometer with thick film pick-up loops'. Together they form a unique fingerprint.