Shear viscosity and nonlinear behaviour of whole blood under large amplitude oscillatory shear

P.C. Sousa, J. Carneiro, R. Vaz, A. Cerejo, F.T. Pinho, M.A. Alves, Monica Oliveira

Research output: Contribution to journalArticlepeer-review

58 Citations (Scopus)
57 Downloads (Pure)

Abstract

We investigated experimentally the rheological behavior of whole human blood subjected to large amplitude oscillatory shear under strain control to assess its nonlinear viscoelastic response. In these rheological tests, the shear stress response presented higher harmonic contributions, revealing the nonlinear behavior of human blood that is associated with changes in its internal microstructure. For the rheological conditions investigated, intra-cycle strain-stiffening and intra-cycle shear-thinning behavior of the human blood samples were observed and quantified based on the Lissajous–Bowditch plots. The results demonstrated that the dissipative nature of whole blood is more intense than its elastic component. We also assessed the effect of adding EDTA anticoagulant on the shear viscosity of whole blood subjected to steady shear flow. We found that the use of anticoagulant in appropriate concentrations did not influence the shear viscosity and that blood samples without anticoagulant
preserved their rheological characteristics approximately for up to 8 minutes before coagulation became significant.
Original languageEnglish
Pages (from-to)269-282
JournalBiorheology
Volume50
Issue number5-6
DOIs
Publication statusPublished - 7 Jan 2014

Keywords

  • whole blood rheology
  • shear viscosity
  • anticoagulant effect
  • large amplitude oscillatory shear (LAOS)