Remote controlled partial discharge acquisition unit

M.H. Foo, J.J. Soraghan, W.H. Siew, J.S. Pearson

Research output: Contribution to conferencePaper

Abstract

Online partial discharge (PD) analysis for underground high voltage cables has major advantages over the offline techniques. Online techniques usually involve PD data acquisition, storage and post-processing of the data. However, the data acquisition process can be time consuming and troublesome because of design procedures and protocols required before commencement of data acquisition. This paper presents a robust remote controlled partial discharge acquisition unit for underground high voltage cable networks. This system is uniquely designed to incorporate the difficulties of accessibility, especially for remotely located
substations. Real field data from a 33kV network is included in the paper.

Conference

Conference17th International Conference on Electricity Distribution (CIRED 2003)
CountrySpain
CityBarcelona
Period12/05/0315/05/03

Fingerprint

Partial discharges
Data acquisition
Cables
Electric potential
Processing

Keywords

  • remote controlled
  • partial discharge
  • acquisition unit

Cite this

Foo, M. H., Soraghan, J. J., Siew, W. H., & Pearson, J. S. (2003). Remote controlled partial discharge acquisition unit. Paper presented at 17th International Conference on Electricity Distribution (CIRED 2003), Barcelona, Spain.
Foo, M.H. ; Soraghan, J.J. ; Siew, W.H. ; Pearson, J.S. / Remote controlled partial discharge acquisition unit. Paper presented at 17th International Conference on Electricity Distribution (CIRED 2003), Barcelona, Spain.4 p.
@conference{948ea8f3f6794b0fa287ab8637f93ec8,
title = "Remote controlled partial discharge acquisition unit",
abstract = "Online partial discharge (PD) analysis for underground high voltage cables has major advantages over the offline techniques. Online techniques usually involve PD data acquisition, storage and post-processing of the data. However, the data acquisition process can be time consuming and troublesome because of design procedures and protocols required before commencement of data acquisition. This paper presents a robust remote controlled partial discharge acquisition unit for underground high voltage cable networks. This system is uniquely designed to incorporate the difficulties of accessibility, especially for remotely locatedsubstations. Real field data from a 33kV network is included in the paper.",
keywords = "remote controlled, partial discharge, acquisition unit",
author = "M.H. Foo and J.J. Soraghan and W.H. Siew and J.S. Pearson",
year = "2003",
month = "5",
language = "English",
note = "17th International Conference on Electricity Distribution (CIRED 2003) ; Conference date: 12-05-2003 Through 15-05-2003",

}

Foo, MH, Soraghan, JJ, Siew, WH & Pearson, JS 2003, 'Remote controlled partial discharge acquisition unit' Paper presented at 17th International Conference on Electricity Distribution (CIRED 2003), Barcelona, Spain, 12/05/03 - 15/05/03, .

Remote controlled partial discharge acquisition unit. / Foo, M.H.; Soraghan, J.J.; Siew, W.H.; Pearson, J.S.

2003. Paper presented at 17th International Conference on Electricity Distribution (CIRED 2003), Barcelona, Spain.

Research output: Contribution to conferencePaper

TY - CONF

T1 - Remote controlled partial discharge acquisition unit

AU - Foo, M.H.

AU - Soraghan, J.J.

AU - Siew, W.H.

AU - Pearson, J.S.

PY - 2003/5

Y1 - 2003/5

N2 - Online partial discharge (PD) analysis for underground high voltage cables has major advantages over the offline techniques. Online techniques usually involve PD data acquisition, storage and post-processing of the data. However, the data acquisition process can be time consuming and troublesome because of design procedures and protocols required before commencement of data acquisition. This paper presents a robust remote controlled partial discharge acquisition unit for underground high voltage cable networks. This system is uniquely designed to incorporate the difficulties of accessibility, especially for remotely locatedsubstations. Real field data from a 33kV network is included in the paper.

AB - Online partial discharge (PD) analysis for underground high voltage cables has major advantages over the offline techniques. Online techniques usually involve PD data acquisition, storage and post-processing of the data. However, the data acquisition process can be time consuming and troublesome because of design procedures and protocols required before commencement of data acquisition. This paper presents a robust remote controlled partial discharge acquisition unit for underground high voltage cable networks. This system is uniquely designed to incorporate the difficulties of accessibility, especially for remotely locatedsubstations. Real field data from a 33kV network is included in the paper.

KW - remote controlled

KW - partial discharge

KW - acquisition unit

M3 - Paper

ER -

Foo MH, Soraghan JJ, Siew WH, Pearson JS. Remote controlled partial discharge acquisition unit. 2003. Paper presented at 17th International Conference on Electricity Distribution (CIRED 2003), Barcelona, Spain.