Pulse plating of copper from deep eutectic solvents

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

The effect of pulse parameters on the deposition of copper from a chloride-based deep eutectic solvent (DES) was investigated. While satisfactory deposits could be obtained for some pulse conditions, at small duty cycles or long off-times the current efficiencies obtained were very low. These findings were consistent with a corrosion process occurring during the off-time, most likely the comproportionation reaction: Cu + CuIICl4 2- → 2CuICl2 - . Initial experimental results were consistent with the corrosion rate being controlled by the transport of the CuIICl4 2- species to the electrode surface. With this assumption, a simple corrosion model was developed to account for the observed loss in current efficiency as a function of the pulse conditions. While this model broadly predicts the observed results some discrepancy between the observed and measured were noted.

Fingerprint

Plating
Eutectics
Copper
Corrosion
Corrosion rate
Chlorides
Deposits
Electrodes

Keywords

  • pulse parameters
  • copper deposition
  • deep eutectic solvents
  • corosion process
  • ionic liquids

Cite this

@article{277898c832664abeb5ac3f856ac7debc,
title = "Pulse plating of copper from deep eutectic solvents",
abstract = "The effect of pulse parameters on the deposition of copper from a chloride-based deep eutectic solvent (DES) was investigated. While satisfactory deposits could be obtained for some pulse conditions, at small duty cycles or long off-times the current efficiencies obtained were very low. These findings were consistent with a corrosion process occurring during the off-time, most likely the comproportionation reaction: Cu + CuIICl4 2- → 2CuICl2 - . Initial experimental results were consistent with the corrosion rate being controlled by the transport of the CuIICl4 2- species to the electrode surface. With this assumption, a simple corrosion model was developed to account for the observed loss in current efficiency as a function of the pulse conditions. While this model broadly predicts the observed results some discrepancy between the observed and measured were noted.",
keywords = "pulse parameters, copper deposition, deep eutectic solvents, corosion process, ionic liquids",
author = "Todd Green and Xiaomeng Su and Sudipta Roy",
year = "2017",
month = "8",
day = "1",
doi = "10.1149/07711.1247ecst",
language = "English",
volume = "77",
pages = "1247--1253",
journal = "ECS Transactions",
issn = "1938-5862",
number = "11",

}

Pulse plating of copper from deep eutectic solvents. / Green, Todd; Su, Xiaomeng; Roy, Sudipta.

In: ECS Transactions, Vol. 77, No. 11, 01.08.2017, p. 1247-1253.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Pulse plating of copper from deep eutectic solvents

AU - Green, Todd

AU - Su, Xiaomeng

AU - Roy, Sudipta

PY - 2017/8/1

Y1 - 2017/8/1

N2 - The effect of pulse parameters on the deposition of copper from a chloride-based deep eutectic solvent (DES) was investigated. While satisfactory deposits could be obtained for some pulse conditions, at small duty cycles or long off-times the current efficiencies obtained were very low. These findings were consistent with a corrosion process occurring during the off-time, most likely the comproportionation reaction: Cu + CuIICl4 2- → 2CuICl2 - . Initial experimental results were consistent with the corrosion rate being controlled by the transport of the CuIICl4 2- species to the electrode surface. With this assumption, a simple corrosion model was developed to account for the observed loss in current efficiency as a function of the pulse conditions. While this model broadly predicts the observed results some discrepancy between the observed and measured were noted.

AB - The effect of pulse parameters on the deposition of copper from a chloride-based deep eutectic solvent (DES) was investigated. While satisfactory deposits could be obtained for some pulse conditions, at small duty cycles or long off-times the current efficiencies obtained were very low. These findings were consistent with a corrosion process occurring during the off-time, most likely the comproportionation reaction: Cu + CuIICl4 2- → 2CuICl2 - . Initial experimental results were consistent with the corrosion rate being controlled by the transport of the CuIICl4 2- species to the electrode surface. With this assumption, a simple corrosion model was developed to account for the observed loss in current efficiency as a function of the pulse conditions. While this model broadly predicts the observed results some discrepancy between the observed and measured were noted.

KW - pulse parameters

KW - copper deposition

KW - deep eutectic solvents

KW - corosion process

KW - ionic liquids

UR - http://ecst.ecsdl.org/

U2 - 10.1149/07711.1247ecst

DO - 10.1149/07711.1247ecst

M3 - Article

VL - 77

SP - 1247

EP - 1253

JO - ECS Transactions

T2 - ECS Transactions

JF - ECS Transactions

SN - 1938-5862

IS - 11