Abstract
Electrical breakdown in air in a point-plane topology involves complex processes that are still not fully understood. Unlike uniform-field topologies, the highly-divergent fields produced by point-plane topologies create pre-breakdown corona with volumetric space charge. It is known that space charges developed by corona discharge have significant impacts on the breakdown voltage in non-uniform electrode topologies. With large inter-electrode gaps (>cm) the breakdown voltage for a HV point cathode in air at atmospheric pressure is noticeably larger than a HV point anode. However, this paper shows that in shorter point-plane gaps in air (less than ~10 mm), in the air pressure range 0.1-0.35 MPa, an HV point anode has a similar breakdown voltage which eventually is surpassed by the HV point cathode as the inter-electrode gap is increased. The inter-electrode gap at which the HV cathode has a higher hold-off voltage is found to be dependent on the gas pressure and radius of the point electrode.
Original language | English |
---|---|
Pages (from-to) | 1815-1822 |
Number of pages | 8 |
Journal | IEEE Transactions on Dielectrics and Electrical Insulation |
Volume | 22 |
Issue number | 4 |
Publication status | Published - Aug 2015 |