Partial discharge detection and location in transformers using UHF techniques

Martin Judd

Research output: Chapter in Book/Report/Conference proceedingChapter

Abstract

Ultra-high frequency (UHF) methods for detecting and locating partial discharges (PD) are well established for gas insulated equipment. This paper provides an overview of their application to power transformers, discussing practicalities, capabilities and challenges. In recent years, UHF PD detection has proved helpful to manufacturers as a tool for enhancing quality control. The technique can now form a valuable addition to the suite of on-line monitoring technologies available for power transformers. A key aspect discussed in this paper is the installation of sensors, which must have an electromagnetic `view' into the Faraday cage of the tank. Locating PD sources by time-of-flight methods in transformers requires accurate spatial resolution in three dimensions in the presence of large conducting components inside the tank that often block the line of sight between PD source and sensor. For this reason, instead of an `empty box' representation, modeling techniques are used to account for the internal structure of the transformer so that observed time differences among PD signals received at different sensors can be interpreted more realistically. The PD location procedure is illustrated by means of practical results, which indicate that PD sources can be located typically to within 0.3 m in a power transformer.
LanguageEnglish
Title of host publicationElectromagnetic Transients in Transformer and Rotating Machine Windings
EditorsQi (Charles) Su
Place of PublicationHershey, Pennsylvania (USA)
Pages487-520
Number of pages35
Edition1
DOIs
Publication statusPublished - Jul 2012

Fingerprint

Partial discharges
Power transformers
Sensors
Quality control
Monitoring
Gases

Keywords

  • partial discharge measurement
  • partial discharge
  • UHF techniques

Cite this

Judd, M. (2012). Partial discharge detection and location in transformers using UHF techniques. In Q. C. Su (Ed.), Electromagnetic Transients in Transformer and Rotating Machine Windings (1 ed., pp. 487-520). Hershey, Pennsylvania (USA). https://doi.org/10.4018/978-1-4666-1921-0.ch013
Judd, Martin. / Partial discharge detection and location in transformers using UHF techniques. Electromagnetic Transients in Transformer and Rotating Machine Windings. editor / Qi (Charles) Su. 1. ed. Hershey, Pennsylvania (USA), 2012. pp. 487-520
@inbook{6c00d7e2ca0d41be890ecc879318f2bd,
title = "Partial discharge detection and location in transformers using UHF techniques",
abstract = "Ultra-high frequency (UHF) methods for detecting and locating partial discharges (PD) are well established for gas insulated equipment. This paper provides an overview of their application to power transformers, discussing practicalities, capabilities and challenges. In recent years, UHF PD detection has proved helpful to manufacturers as a tool for enhancing quality control. The technique can now form a valuable addition to the suite of on-line monitoring technologies available for power transformers. A key aspect discussed in this paper is the installation of sensors, which must have an electromagnetic `view' into the Faraday cage of the tank. Locating PD sources by time-of-flight methods in transformers requires accurate spatial resolution in three dimensions in the presence of large conducting components inside the tank that often block the line of sight between PD source and sensor. For this reason, instead of an `empty box' representation, modeling techniques are used to account for the internal structure of the transformer so that observed time differences among PD signals received at different sensors can be interpreted more realistically. The PD location procedure is illustrated by means of practical results, which indicate that PD sources can be located typically to within 0.3 m in a power transformer.",
keywords = "partial discharge measurement, partial discharge , UHF techniques",
author = "Martin Judd",
year = "2012",
month = "7",
doi = "10.4018/978-1-4666-1921-0.ch013",
language = "English",
isbn = "9781466619210",
pages = "487--520",
editor = "Su, {Qi (Charles)}",
booktitle = "Electromagnetic Transients in Transformer and Rotating Machine Windings",
edition = "1",

}

Judd, M 2012, Partial discharge detection and location in transformers using UHF techniques. in QC Su (ed.), Electromagnetic Transients in Transformer and Rotating Machine Windings. 1 edn, Hershey, Pennsylvania (USA), pp. 487-520. https://doi.org/10.4018/978-1-4666-1921-0.ch013

Partial discharge detection and location in transformers using UHF techniques. / Judd, Martin.

Electromagnetic Transients in Transformer and Rotating Machine Windings. ed. / Qi (Charles) Su. 1. ed. Hershey, Pennsylvania (USA), 2012. p. 487-520.

Research output: Chapter in Book/Report/Conference proceedingChapter

TY - CHAP

T1 - Partial discharge detection and location in transformers using UHF techniques

AU - Judd, Martin

PY - 2012/7

Y1 - 2012/7

N2 - Ultra-high frequency (UHF) methods for detecting and locating partial discharges (PD) are well established for gas insulated equipment. This paper provides an overview of their application to power transformers, discussing practicalities, capabilities and challenges. In recent years, UHF PD detection has proved helpful to manufacturers as a tool for enhancing quality control. The technique can now form a valuable addition to the suite of on-line monitoring technologies available for power transformers. A key aspect discussed in this paper is the installation of sensors, which must have an electromagnetic `view' into the Faraday cage of the tank. Locating PD sources by time-of-flight methods in transformers requires accurate spatial resolution in three dimensions in the presence of large conducting components inside the tank that often block the line of sight between PD source and sensor. For this reason, instead of an `empty box' representation, modeling techniques are used to account for the internal structure of the transformer so that observed time differences among PD signals received at different sensors can be interpreted more realistically. The PD location procedure is illustrated by means of practical results, which indicate that PD sources can be located typically to within 0.3 m in a power transformer.

AB - Ultra-high frequency (UHF) methods for detecting and locating partial discharges (PD) are well established for gas insulated equipment. This paper provides an overview of their application to power transformers, discussing practicalities, capabilities and challenges. In recent years, UHF PD detection has proved helpful to manufacturers as a tool for enhancing quality control. The technique can now form a valuable addition to the suite of on-line monitoring technologies available for power transformers. A key aspect discussed in this paper is the installation of sensors, which must have an electromagnetic `view' into the Faraday cage of the tank. Locating PD sources by time-of-flight methods in transformers requires accurate spatial resolution in three dimensions in the presence of large conducting components inside the tank that often block the line of sight between PD source and sensor. For this reason, instead of an `empty box' representation, modeling techniques are used to account for the internal structure of the transformer so that observed time differences among PD signals received at different sensors can be interpreted more realistically. The PD location procedure is illustrated by means of practical results, which indicate that PD sources can be located typically to within 0.3 m in a power transformer.

KW - partial discharge measurement

KW - partial discharge

KW - UHF techniques

UR - http://dx.doi.org/10.1109/EIC.2011.5996146

UR - http://www.igi-global.com/chapter/partial-discharge-detection-location-transformers/68884

U2 - 10.4018/978-1-4666-1921-0.ch013

DO - 10.4018/978-1-4666-1921-0.ch013

M3 - Chapter

SN - 9781466619210

SP - 487

EP - 520

BT - Electromagnetic Transients in Transformer and Rotating Machine Windings

A2 - Su, Qi (Charles)

CY - Hershey, Pennsylvania (USA)

ER -

Judd M. Partial discharge detection and location in transformers using UHF techniques. In Su QC, editor, Electromagnetic Transients in Transformer and Rotating Machine Windings. 1 ed. Hershey, Pennsylvania (USA). 2012. p. 487-520 https://doi.org/10.4018/978-1-4666-1921-0.ch013