Optical properties of germania and titania at 1064 nm and at 1550 nm

D Diksha, A Amato, V Spagnuolo, G i Mcghee, M Chicoine, C Clark, S Hill, J Hough, R Johnston, R Keil, N Mavridi, S Reid, S Rowan, T Schapals, F Schiettekatte, S c Tait, I W Martin, J Steinlechner

Research output: Contribution to journalArticlepeer-review

2 Citations (Scopus)
17 Downloads (Pure)

Abstract

One of the main noise sources in current gravitational-wave detectors is the thermal noise of the high-reflectivity coatings on the main interferometer optics. Coating thermal noise is dominated by the mechanical loss of the highrefractive index material within the coating stacks, Ta2O5 mixed with TiO2. For upgrades to room-temperature detectors, a mixture of GeO2 and TiO2 is an interesting alternative candidate coating material. While the rather low refractive index of GeO2 increases with increasing TiO2 content, a higher TiO2 content results in a lower threshold temperature before heat treatment leads to crystallisation, and potentially to a degradation of optical properties. For future cryogenic detectors, on the other hand, a higher TiO2 content is beneficial as the TiO2 suppresses the low-temperature mechanical loss peak of GeO2. In this paper, we present the optical properties of coatings—produced byplasma-assisted ion-beam evaporation—with high TiO2 content at 1550 nm, a laser wavelength considered for cryogenic gravitational-wave detectors, as a function of heat-treatment temperature. For comparison, the absorption of pure GeO2wasalsomeasured.Furthermore,resultsatthecurrently-usedwavelength of 1064 nm are presented.
Original languageEnglish
Article number125006
Number of pages12
JournalClassical and Quantum Gravity
Volume41
Issue number12
DOIs
Publication statusPublished - 17 May 2024

Funding

We are grateful for financial support from STFC (ST/V005634/1, ST/V001736/1), the University of Glasgow, the Royal Society (RG110331), ETpathfinder (Interreg VlaanderenNederland), E-TEST (Interreg Euregio Meuse-Rhine), and the Province of Limburg. We thank our colleagues within the LIGO Scientific Collaboration and Virgo Collaboration and within SUPA for their interest in this work. The work done at U. Montréal was supported by the NSERC, and the FRQNT through the RQMP. This publication is part of the project with Project No. VI.Vidi.203.062 financed by the Dutch Research Council (NWO). This article has LIGO Document No. P2300408.

Keywords

  • gravitational-wave detectors
  • coating thermal noise
  • titania
  • low temperature
  • absorption