TY - JOUR
T1 - On-line duplex molecularly imprinted solid-phase extraction for analysis of low abundant biomarkers in human serum by liquid chromatography-tandem mass spectrometry
AU - McKitterick, Nicholas
AU - Bicak, Tugrul Cem
AU - Switnicka-Plak, Magdalena A.
AU - Cormack, Peter A.G.
AU - Reubsaet, Léon
AU - Grønhaug Halvorsen, Trine
PY - 2021/10/11
Y1 - 2021/10/11
N2 - In the present work, a pair of molecularly imprinted polymers (MIPs) targeting distinct peptide targets were packed into trap columns and combined for automated duplex analysis of two low abundant small cell lung cancer biomarkers (neuron-specific enolase [NSE] and progastrin-releasing peptide [ProGRP]). Optimization of the on-line molecularly imprinted solid-phase extraction (MISPE) protocol ensured that the MIPs had the necessary affinity and selectivity towards their respective signature peptide targets – NLLGLIEAK (ProGRP) and ELPLYR (NSE) – in serum. Two duplex formats were evaluated: a physical mixture of the two MIPs (1:1 w/w ratio) inside a single trap column, and two separate MIP trap columns connected in series. Both duplex formats enabled the extraction of the peptides from serum. However, the trap columns in series gave superior extraction efficiency (85.8±3.8% and 49.1±6.7% for NLLGLIEAK and ELPLYR, respectively). The optimized protocol showed satisfactory intraday (RSD≤23.4 %) and interday (RSD≤14.6%) precision. Duplex analysis of NSE and ProGRP spiked into digested human serum was linear (R 2≥0.98) over the disease range (0.3-30 nM). The estimated limit of detection (LOD) and limit of quantification (LOQ) were 0.11 nM and 0.37 nM, respectively, for NSE, and 0.06 nM and 0.2 nM, respectively, for ProGRP. Both biomarkers were determined at clinically relevant levels. To the best of our knowledge, the present work is the first report of an automated MIP duplex biomarker analysis. It represents a proof of concept for clinically viable duplex analysis of low abundant biomarkers present in human serum or other biofluids.
AB - In the present work, a pair of molecularly imprinted polymers (MIPs) targeting distinct peptide targets were packed into trap columns and combined for automated duplex analysis of two low abundant small cell lung cancer biomarkers (neuron-specific enolase [NSE] and progastrin-releasing peptide [ProGRP]). Optimization of the on-line molecularly imprinted solid-phase extraction (MISPE) protocol ensured that the MIPs had the necessary affinity and selectivity towards their respective signature peptide targets – NLLGLIEAK (ProGRP) and ELPLYR (NSE) – in serum. Two duplex formats were evaluated: a physical mixture of the two MIPs (1:1 w/w ratio) inside a single trap column, and two separate MIP trap columns connected in series. Both duplex formats enabled the extraction of the peptides from serum. However, the trap columns in series gave superior extraction efficiency (85.8±3.8% and 49.1±6.7% for NLLGLIEAK and ELPLYR, respectively). The optimized protocol showed satisfactory intraday (RSD≤23.4 %) and interday (RSD≤14.6%) precision. Duplex analysis of NSE and ProGRP spiked into digested human serum was linear (R 2≥0.98) over the disease range (0.3-30 nM). The estimated limit of detection (LOD) and limit of quantification (LOQ) were 0.11 nM and 0.37 nM, respectively, for NSE, and 0.06 nM and 0.2 nM, respectively, for ProGRP. Both biomarkers were determined at clinically relevant levels. To the best of our knowledge, the present work is the first report of an automated MIP duplex biomarker analysis. It represents a proof of concept for clinically viable duplex analysis of low abundant biomarkers present in human serum or other biofluids.
KW - LC-MS/MS
KW - low-abundant biomarkers
KW - molecularly imprinted polymers
KW - multiplexing
KW - on-line SPE
KW - targeted bottom-up proteomics
U2 - 10.1016/j.chroma.2021.462490
DO - 10.1016/j.chroma.2021.462490
M3 - Article
SN - 0021-9673
VL - 1655
JO - Journal of Chromatography A
JF - Journal of Chromatography A
M1 - 462490
ER -