Noninvasive detection of ischemic vascular damage in a pig model of liver donation after circulatory death

Katherine J.I. Ember, Fiona Hunt, Lauren E. Jamieson, John M. Hallett, Hannah Esser, Timothy J. Kendall, R. Eddie Clutton, Rachael Gregson, Karen Faulds, Stuart J. Forbes, Gabriel C. Oniscu, Colin J. Campbell*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

8 Citations (Scopus)
48 Downloads (Pure)

Abstract

Background and Aims: Liver graft quality is evaluated by visual inspection prior to transplantation, a process highly dependent on the surgeon's experience. We present an objective, noninvasive, quantitative way of assessing liver quality in real time using Raman spectroscopy, a laser-based tool for analyzing biomolecular composition. Approach and Results: A porcine model of donation after circulatory death (DCD) with normothermic regional perfusion (NRP) allowed assessment of liver quality premortem, during warm ischemia (WI) and post-NRP. Ten percent of circulating blood volume was removed in half of experiments to simulate blood recovery for DCD heart removal. Left median lobe biopsies were obtained before circulatory arrest, after 45 minutes of WI, and after 2 hours of NRP and analyzed using spontaneous Raman spectroscopy, stimulated Raman spectroscopy (SRS), and staining. Measurements were also taken in situ from the porcine liver using a handheld Raman spectrometer at these time points from left median and right lateral lobes. Raman microspectroscopy detected congestion during WI by measurement of the intrinsic Raman signal of hemoglobin in red blood cells (RBCs), eliminating the need for exogenous labels. Critically, this microvascular damage was not observed during WI when 10% of circulating blood was removed before cardiac arrest. Two hours of NRP effectively cleared RBCs from congested livers. Intact RBCs were visualized rapidly at high resolution using SRS. Optical properties of ischemic livers were significantly different from preischemic and post-NRP livers as measured using a handheld Raman spectrometer. Conclusions: Raman spectroscopy is an effective tool for detecting microvascular damage which could assist the decision to use marginal livers for transplantation. Reducing the volume of circulating blood before circulatory arrest in DCD may help reduce microvascular damage.

Original languageEnglish
Pages (from-to)428-443
Number of pages16
JournalHepatology
Volume74
Issue number1
Early online date8 Jan 2021
DOIs
Publication statusPublished - 31 Jul 2021

Funding

Thanks to Bertrand Vernay for assistance with QuPath cell counting, Mike Millar of QMRI SURF imaging facility, and members of the Forbes, Campbell, and Faulds labs, especially Janet Man, Sarah McAughtrie, and Amy Morrison. Thanks to Steve Wigmore of the Royal Infirmary of Edinburgh for assistance in application for the Confidence in Concept grant. Thank you to the Royal (Dick) School of Veterinary Sciences, especially Timothy King for help with the pig transplant experiments. Thanks also to Henri Leuvenink and Leonie Venema of Groeningen University and Arjan van der Plaats, chief technology officer at Organ Assist, the Netherlands.

Keywords

  • noninvasive
  • detection
  • ischemic vascular damage
  • pig
  • model
  • liver donation
  • circulatory death

Fingerprint

Dive into the research topics of 'Noninvasive detection of ischemic vascular damage in a pig model of liver donation after circulatory death'. Together they form a unique fingerprint.