TY - JOUR
T1 - Microparticle image velocimetry approach to flow measurements in isolated contracting lymphatic vessels
AU - Margaris, Konstantinos N.
AU - Nepiyushchikh, Zhanna
AU - Zawieja, David C.
AU - Moore Jr, James
AU - Black, Richard A.
PY - 2016/2/1
Y1 - 2016/2/1
N2 - We describe the development of an optical flow visualization method for resolving the flow velocity vector field in lymphatic vessels, in vitro. The aim is to develop an experimental protocol for accurately estimating flow parameters, such as flow rate and shear stresses, with high spatial and temporal resolution. Previous studies in situ have relied on lymphocytes as tracers, but their low density resulted in a reduced spatial resolution whereas the assumption that the flow was fully developed in order to determine the flow parameters of interest may not be valid, especially in the vicinity of the valves, where the flow is undoubtedly more complex. To overcome these issues, we have applied the time-resolved micro-Particle Image Velocimetry technique, a well-established method that can provide increased spatial and temporal resolution that this transient flow demands. To that end, we have developed a custom light source, utilizing high-power light-emitting diodes, and associated control and image processing software. This manuscript reports the performance of the system and the results of a series of preliminary experiments performed on vessels isolated from rat mesenteries, demonstrating, for the first time, the successful application of the micro-PIV technique in these vessels.
AB - We describe the development of an optical flow visualization method for resolving the flow velocity vector field in lymphatic vessels, in vitro. The aim is to develop an experimental protocol for accurately estimating flow parameters, such as flow rate and shear stresses, with high spatial and temporal resolution. Previous studies in situ have relied on lymphocytes as tracers, but their low density resulted in a reduced spatial resolution whereas the assumption that the flow was fully developed in order to determine the flow parameters of interest may not be valid, especially in the vicinity of the valves, where the flow is undoubtedly more complex. To overcome these issues, we have applied the time-resolved micro-Particle Image Velocimetry technique, a well-established method that can provide increased spatial and temporal resolution that this transient flow demands. To that end, we have developed a custom light source, utilizing high-power light-emitting diodes, and associated control and image processing software. This manuscript reports the performance of the system and the results of a series of preliminary experiments performed on vessels isolated from rat mesenteries, demonstrating, for the first time, the successful application of the micro-PIV technique in these vessels.
KW - lymphatic system
KW - lymphangion
KW - micro-PIV
KW - flow measurements
KW - physiological flows
KW - LED
UR - http://biomedicaloptics.spiedigitallibrary.org/journal.aspx
U2 - 10.1117/1.JBO.21.2.025002
DO - 10.1117/1.JBO.21.2.025002
M3 - Article
SN - 1083-3668
VL - 21
JO - Journal of Biomedical Optics
JF - Journal of Biomedical Optics
IS - 2
M1 - 025002
ER -