Measuring the daily stepping activity of people with transtibial amputation using the ActivPAL™ activity monitor

Adrianus Buis, Tim Dumbleton, Kevin D. Murray, Brendan F. McHugh, Geoffrey McKay, Sandra Sexton

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

This study compared the general activity over one week and detailed activity during a 24-hour period, of 48 established unilateral transtibial prostheses users. Activity was measured by instrumenting their prescribed prosthesis, which they have been using for a minimum of 6 month, with the ActivPAL™ activity monitor. Half (n=24) were fitted with a prostheses with total surface bearing (TSB) pressure-cast sockets (Hands-off) and the other half (n=24) had been wearing prostheses with hand-cast (Hands-on) patella tendon bearing (PTB) sockets. As a prerequisite, the long-term reliability of the ActivPAL™ activity monitor was assessed and it was found to exhibit a high level of consistency between devices (Interclass Correlation Coefficient (ICC) of 0.997 over a 24-hour period). The monitors were utilized to examine the activity levels of two groups of transtibial prostheses users wearing their own prosthesis. Results indicated that both subject groups were active throughout the day, walking on average over 8,000 steps. No statistically significant difference in daily stepping activity was seen between the two groups (p=0.173). Despite differences in prosthetic socket design the daily activity profiles of both subject groups were similar.
LanguageEnglish
Pages43-47
Number of pages4
JournalJournal of Prosthetics and Orthotics
Volume26
Issue number1
DOIs
Publication statusPublished - 1 Jan 2014

Fingerprint

Prosthetics
Amputation
Prostheses and Implants
Bearings (structural)
Hand
Tendons
Patellar Ligament
Walking
Pressure
Equipment and Supplies

Keywords

  • daily
  • stepping activity
  • measurement
  • measuring
  • ActivPAL?
  • trans-tibial amputation
  • activity monitor

Cite this

@article{7f8dfb2201604f1585172cc23bb88f7a,
title = "Measuring the daily stepping activity of people with transtibial amputation using the ActivPAL™ activity monitor",
abstract = "This study compared the general activity over one week and detailed activity during a 24-hour period, of 48 established unilateral transtibial prostheses users. Activity was measured by instrumenting their prescribed prosthesis, which they have been using for a minimum of 6 month, with the ActivPAL™ activity monitor. Half (n=24) were fitted with a prostheses with total surface bearing (TSB) pressure-cast sockets (Hands-off) and the other half (n=24) had been wearing prostheses with hand-cast (Hands-on) patella tendon bearing (PTB) sockets. As a prerequisite, the long-term reliability of the ActivPAL™ activity monitor was assessed and it was found to exhibit a high level of consistency between devices (Interclass Correlation Coefficient (ICC) of 0.997 over a 24-hour period). The monitors were utilized to examine the activity levels of two groups of transtibial prostheses users wearing their own prosthesis. Results indicated that both subject groups were active throughout the day, walking on average over 8,000 steps. No statistically significant difference in daily stepping activity was seen between the two groups (p=0.173). Despite differences in prosthetic socket design the daily activity profiles of both subject groups were similar.",
keywords = "daily, stepping activity, measurement, measuring, ActivPAL? , trans-tibial amputation, activity monitor",
author = "Adrianus Buis and Tim Dumbleton and Murray, {Kevin D.} and McHugh, {Brendan F.} and Geoffrey McKay and Sandra Sexton",
year = "2014",
month = "1",
day = "1",
doi = "10.1097/JPO.0000000000000016",
language = "English",
volume = "26",
pages = "43--47",
journal = "Journal of Prosthetics and Orthotics",
issn = "1040-8800",
number = "1",

}

Measuring the daily stepping activity of people with transtibial amputation using the ActivPAL™ activity monitor. / Buis, Adrianus; Dumbleton, Tim; Murray, Kevin D.; McHugh, Brendan F.; McKay, Geoffrey; Sexton, Sandra.

In: Journal of Prosthetics and Orthotics, Vol. 26, No. 1, 01.01.2014, p. 43-47.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Measuring the daily stepping activity of people with transtibial amputation using the ActivPAL™ activity monitor

AU - Buis, Adrianus

AU - Dumbleton, Tim

AU - Murray, Kevin D.

AU - McHugh, Brendan F.

AU - McKay, Geoffrey

AU - Sexton, Sandra

PY - 2014/1/1

Y1 - 2014/1/1

N2 - This study compared the general activity over one week and detailed activity during a 24-hour period, of 48 established unilateral transtibial prostheses users. Activity was measured by instrumenting their prescribed prosthesis, which they have been using for a minimum of 6 month, with the ActivPAL™ activity monitor. Half (n=24) were fitted with a prostheses with total surface bearing (TSB) pressure-cast sockets (Hands-off) and the other half (n=24) had been wearing prostheses with hand-cast (Hands-on) patella tendon bearing (PTB) sockets. As a prerequisite, the long-term reliability of the ActivPAL™ activity monitor was assessed and it was found to exhibit a high level of consistency between devices (Interclass Correlation Coefficient (ICC) of 0.997 over a 24-hour period). The monitors were utilized to examine the activity levels of two groups of transtibial prostheses users wearing their own prosthesis. Results indicated that both subject groups were active throughout the day, walking on average over 8,000 steps. No statistically significant difference in daily stepping activity was seen between the two groups (p=0.173). Despite differences in prosthetic socket design the daily activity profiles of both subject groups were similar.

AB - This study compared the general activity over one week and detailed activity during a 24-hour period, of 48 established unilateral transtibial prostheses users. Activity was measured by instrumenting their prescribed prosthesis, which they have been using for a minimum of 6 month, with the ActivPAL™ activity monitor. Half (n=24) were fitted with a prostheses with total surface bearing (TSB) pressure-cast sockets (Hands-off) and the other half (n=24) had been wearing prostheses with hand-cast (Hands-on) patella tendon bearing (PTB) sockets. As a prerequisite, the long-term reliability of the ActivPAL™ activity monitor was assessed and it was found to exhibit a high level of consistency between devices (Interclass Correlation Coefficient (ICC) of 0.997 over a 24-hour period). The monitors were utilized to examine the activity levels of two groups of transtibial prostheses users wearing their own prosthesis. Results indicated that both subject groups were active throughout the day, walking on average over 8,000 steps. No statistically significant difference in daily stepping activity was seen between the two groups (p=0.173). Despite differences in prosthetic socket design the daily activity profiles of both subject groups were similar.

KW - daily

KW - stepping activity

KW - measurement

KW - measuring

KW - ActivPAL?

KW - trans-tibial amputation

KW - activity monitor

UR - http://journals.lww.com/jpojournal/Abstract/2014/01000/Measuring_the_Daily_Stepping_Activity_of_People.6.aspx

UR - http://www.oandp.org/jpo/library/index/2014_01.asp

U2 - 10.1097/JPO.0000000000000016

DO - 10.1097/JPO.0000000000000016

M3 - Article

VL - 26

SP - 43

EP - 47

JO - Journal of Prosthetics and Orthotics

T2 - Journal of Prosthetics and Orthotics

JF - Journal of Prosthetics and Orthotics

SN - 1040-8800

IS - 1

ER -