Interpretation of partial discharge activity in the presence of harmonics

Research output: Contribution to conferencePaperpeer-review

234 Downloads (Pure)

Abstract

Recent work has identified that circumstances of equipment operation can radically change condition monitoring data. This contribution investigates the significance of considering circumstance monitoring on the diagnostic interpretation of such condition monitoring data. Electrical treeing partial discharge data have been subjected to a data mining investigation, providing a platform for classification of harmonic influenced partial discharge patterns. The Total Harmonic Distortion (THD) index was varied to a maximum of 40%. The results show progressive development for interpretation of condition monitoring data, improving the asset manager's holistic view of an asset's health.
Original languageEnglish
DOIs
Publication statusPublished - Jul 2010
Event10th IEEE International Conference on Solid Dielectrics (ICSD) - Potsdam, Germany
Duration: 4 Jul 20109 Jul 2010

Conference

Conference10th IEEE International Conference on Solid Dielectrics (ICSD)
CityPotsdam, Germany
Period4/07/109/07/10

Keywords

  • partial discharge activity
  • harmonics
  • solid dielectrics