Abstract

In an accompanying paper, a new integrated structural analysis tool using the LMM framework for the assessment of design limits in plasticity including load carrying capacity, shakedown limit, ratchet limit and steady state cyclic response of structures was developed using Abaqus CAE plug-­‐ins with graphical user interfaces. In the present paper, a demonstration of the use of this new LMM analysis tool is provided. A header branch pipe in a typical AGR power plant is analysed as a worked example of the current demonstration and verification of the LMM tool within the context of an R5 assessment. The detailed shakedown analysis, steady state cycle and ratchet analysis are carried out for the chosen header branch pipe. The comparisons of the LMM solutions with the results based on the R5 procedure and the step-­‐by-­‐step elastic-­‐plastic FEA verify the accuracy, convenience and efficiency of this new integrated LMM structural analysis tool.
LanguageEnglish
Pages152-161
JournalInternational Journal of Pressure Vessels and Piping
Volume120-121
Early online date23 May 2014
DOIs
Publication statusPublished - Aug 2014

Fingerprint

Structural analysis
Demonstrations
Pipe
Computer aided engineering
Load limits
Graphical user interfaces
Plasticity
Power plants
Plastics
Finite element method

Keywords

  • linear matching method
  • load carrying capacity
  • shakedown limit
  • ratchet limit
  • steady state cycle

Cite this

@article{7321b8ca4e144c3cb51b0c1a2cc9ae54,
title = "Integrated structural analysis tool using linear matching method part 2: Application and verification",
abstract = "In an accompanying paper, a new integrated structural analysis tool using the LMM framework for the assessment of design limits in plasticity including load carrying capacity, shakedown limit, ratchet limit and steady state cyclic response of structures was developed using Abaqus CAE plug-­‐ins with graphical user interfaces. In the present paper, a demonstration of the use of this new LMM analysis tool is provided. A header branch pipe in a typical AGR power plant is analysed as a worked example of the current demonstration and verification of the LMM tool within the context of an R5 assessment. The detailed shakedown analysis, steady state cycle and ratchet analysis are carried out for the chosen header branch pipe. The comparisons of the LMM solutions with the results based on the R5 procedure and the step-­‐by-­‐step elastic-­‐plastic FEA verify the accuracy, convenience and efficiency of this new integrated LMM structural analysis tool.",
keywords = "linear matching method , load carrying capacity, shakedown limit, ratchet limit, steady state cycle",
author = "Haofeng Chen and James Ure and David Tipping",
year = "2014",
month = "8",
doi = "10.1016/j.ijpvp.2014.05.005",
language = "English",
volume = "120-121",
pages = "152--161",
journal = "International Journal of Pressure Vessels and Piping",
issn = "0308-0161",

}

Integrated structural analysis tool using linear matching method part 2 : Application and verification. / Chen, Haofeng; Ure, James; Tipping, David.

In: International Journal of Pressure Vessels and Piping, Vol. 120-121, 08.2014, p. 152-161.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Integrated structural analysis tool using linear matching method part 2

T2 - International Journal of Pressure Vessels and Piping

AU - Chen, Haofeng

AU - Ure, James

AU - Tipping, David

PY - 2014/8

Y1 - 2014/8

N2 - In an accompanying paper, a new integrated structural analysis tool using the LMM framework for the assessment of design limits in plasticity including load carrying capacity, shakedown limit, ratchet limit and steady state cyclic response of structures was developed using Abaqus CAE plug-­‐ins with graphical user interfaces. In the present paper, a demonstration of the use of this new LMM analysis tool is provided. A header branch pipe in a typical AGR power plant is analysed as a worked example of the current demonstration and verification of the LMM tool within the context of an R5 assessment. The detailed shakedown analysis, steady state cycle and ratchet analysis are carried out for the chosen header branch pipe. The comparisons of the LMM solutions with the results based on the R5 procedure and the step-­‐by-­‐step elastic-­‐plastic FEA verify the accuracy, convenience and efficiency of this new integrated LMM structural analysis tool.

AB - In an accompanying paper, a new integrated structural analysis tool using the LMM framework for the assessment of design limits in plasticity including load carrying capacity, shakedown limit, ratchet limit and steady state cyclic response of structures was developed using Abaqus CAE plug-­‐ins with graphical user interfaces. In the present paper, a demonstration of the use of this new LMM analysis tool is provided. A header branch pipe in a typical AGR power plant is analysed as a worked example of the current demonstration and verification of the LMM tool within the context of an R5 assessment. The detailed shakedown analysis, steady state cycle and ratchet analysis are carried out for the chosen header branch pipe. The comparisons of the LMM solutions with the results based on the R5 procedure and the step-­‐by-­‐step elastic-­‐plastic FEA verify the accuracy, convenience and efficiency of this new integrated LMM structural analysis tool.

KW - linear matching method

KW - load carrying capacity

KW - shakedown limit

KW - ratchet limit

KW - steady state cycle

UR - http://www.sciencedirect.com/science/article/pii/S0308016114000611

U2 - 10.1016/j.ijpvp.2014.05.005

DO - 10.1016/j.ijpvp.2014.05.005

M3 - Article

VL - 120-121

SP - 152

EP - 161

JO - International Journal of Pressure Vessels and Piping

JF - International Journal of Pressure Vessels and Piping

SN - 0308-0161

ER -