Improving frequency and ROCOF accuracy during faults, for P class Phasor Measurement Units

Andrew Roscoe, Graeme Burt, Gert Rietveld

Research output: Chapter in Book/Report/Conference proceedingConference contribution book

5 Citations (Scopus)

Abstract

Many aspects of Phasor Measurement Unit (PMU) performance are tested using the existing (and evolving) IEEE C37.118 standard. However, at present the reaction of PMUs to power network faults is not assessed under C37.118. Nevertheless, the behaviour of PMUs under such conditions may be important when the entire closed loop of power system measurement, control and response is considered. This paper presents ways in which P class PMU algorithms may be augmented with software which reduces peak frequency excursions during unbalanced faults by factors of typically between 2.5 and 6 with no additional effect on response time, delay or latency. Peak ROCOF excursions are also reduced. In addition, extra filtering which still allows P class response requirements to be met can further reduce excursions, in particular ROCOF. Further improvement of triggering by using midpoint taps of the P class filter, and adaptive filtering, allows peak excursions to be reduced by total factors of between 8 and 40 (or up to 180 for ROCOF), compared to the C37.118 reference device. Steady-state frequency and ROCOF errors during sustained faults or unbalanced operation, particularly under unbalanced conditions, can be reduced by factors of hundreds or thousands compared to the C37.118 reference device.
LanguageEnglish
Title of host publicationProceedings of the 2013 IEEE International Workshop on Applied Measurements for Power Systems (AMPS)
PublisherIEEE
Pages97-102
ISBN (Print)978-1-4673-5571-1
DOIs
Publication statusPublished - Sep 2013
Event2013 IEEE International Workshop on Applied Measurements for Power Systems (AMPS) - Aachen, Germany
Duration: 25 Sep 201326 Sep 2013

Conference

Conference2013 IEEE International Workshop on Applied Measurements for Power Systems (AMPS)
CountryGermany
CityAachen
Period25/09/1326/09/13

Fingerprint

Phasor measurement units
Electric power system measurement
Adaptive filtering
Time delay

Keywords

  • fourier transforms
  • frequency measurement
  • filtering algorithms

Cite this

Roscoe, A., Burt, G., & Rietveld, G. (2013). Improving frequency and ROCOF accuracy during faults, for P class Phasor Measurement Units. In Proceedings of the 2013 IEEE International Workshop on Applied Measurements for Power Systems (AMPS) (pp. 97-102). IEEE. https://doi.org/10.1109/AMPS.2013.6656233
Roscoe, Andrew ; Burt, Graeme ; Rietveld, Gert. / Improving frequency and ROCOF accuracy during faults, for P class Phasor Measurement Units. Proceedings of the 2013 IEEE International Workshop on Applied Measurements for Power Systems (AMPS). IEEE, 2013. pp. 97-102
@inproceedings{07f9ac37efae4879b002eb5bcb9ff500,
title = "Improving frequency and ROCOF accuracy during faults, for P class Phasor Measurement Units",
abstract = "Many aspects of Phasor Measurement Unit (PMU) performance are tested using the existing (and evolving) IEEE C37.118 standard. However, at present the reaction of PMUs to power network faults is not assessed under C37.118. Nevertheless, the behaviour of PMUs under such conditions may be important when the entire closed loop of power system measurement, control and response is considered. This paper presents ways in which P class PMU algorithms may be augmented with software which reduces peak frequency excursions during unbalanced faults by factors of typically between 2.5 and 6 with no additional effect on response time, delay or latency. Peak ROCOF excursions are also reduced. In addition, extra filtering which still allows P class response requirements to be met can further reduce excursions, in particular ROCOF. Further improvement of triggering by using midpoint taps of the P class filter, and adaptive filtering, allows peak excursions to be reduced by total factors of between 8 and 40 (or up to 180 for ROCOF), compared to the C37.118 reference device. Steady-state frequency and ROCOF errors during sustained faults or unbalanced operation, particularly under unbalanced conditions, can be reduced by factors of hundreds or thousands compared to the C37.118 reference device.",
keywords = "fourier transforms, frequency measurement , filtering algorithms",
author = "Andrew Roscoe and Graeme Burt and Gert Rietveld",
year = "2013",
month = "9",
doi = "10.1109/AMPS.2013.6656233",
language = "English",
isbn = "978-1-4673-5571-1",
pages = "97--102",
booktitle = "Proceedings of the 2013 IEEE International Workshop on Applied Measurements for Power Systems (AMPS)",
publisher = "IEEE",

}

Roscoe, A, Burt, G & Rietveld, G 2013, Improving frequency and ROCOF accuracy during faults, for P class Phasor Measurement Units. in Proceedings of the 2013 IEEE International Workshop on Applied Measurements for Power Systems (AMPS). IEEE, pp. 97-102, 2013 IEEE International Workshop on Applied Measurements for Power Systems (AMPS) , Aachen, Germany, 25/09/13. https://doi.org/10.1109/AMPS.2013.6656233

Improving frequency and ROCOF accuracy during faults, for P class Phasor Measurement Units. / Roscoe, Andrew; Burt, Graeme; Rietveld, Gert.

Proceedings of the 2013 IEEE International Workshop on Applied Measurements for Power Systems (AMPS). IEEE, 2013. p. 97-102.

Research output: Chapter in Book/Report/Conference proceedingConference contribution book

TY - GEN

T1 - Improving frequency and ROCOF accuracy during faults, for P class Phasor Measurement Units

AU - Roscoe, Andrew

AU - Burt, Graeme

AU - Rietveld, Gert

PY - 2013/9

Y1 - 2013/9

N2 - Many aspects of Phasor Measurement Unit (PMU) performance are tested using the existing (and evolving) IEEE C37.118 standard. However, at present the reaction of PMUs to power network faults is not assessed under C37.118. Nevertheless, the behaviour of PMUs under such conditions may be important when the entire closed loop of power system measurement, control and response is considered. This paper presents ways in which P class PMU algorithms may be augmented with software which reduces peak frequency excursions during unbalanced faults by factors of typically between 2.5 and 6 with no additional effect on response time, delay or latency. Peak ROCOF excursions are also reduced. In addition, extra filtering which still allows P class response requirements to be met can further reduce excursions, in particular ROCOF. Further improvement of triggering by using midpoint taps of the P class filter, and adaptive filtering, allows peak excursions to be reduced by total factors of between 8 and 40 (or up to 180 for ROCOF), compared to the C37.118 reference device. Steady-state frequency and ROCOF errors during sustained faults or unbalanced operation, particularly under unbalanced conditions, can be reduced by factors of hundreds or thousands compared to the C37.118 reference device.

AB - Many aspects of Phasor Measurement Unit (PMU) performance are tested using the existing (and evolving) IEEE C37.118 standard. However, at present the reaction of PMUs to power network faults is not assessed under C37.118. Nevertheless, the behaviour of PMUs under such conditions may be important when the entire closed loop of power system measurement, control and response is considered. This paper presents ways in which P class PMU algorithms may be augmented with software which reduces peak frequency excursions during unbalanced faults by factors of typically between 2.5 and 6 with no additional effect on response time, delay or latency. Peak ROCOF excursions are also reduced. In addition, extra filtering which still allows P class response requirements to be met can further reduce excursions, in particular ROCOF. Further improvement of triggering by using midpoint taps of the P class filter, and adaptive filtering, allows peak excursions to be reduced by total factors of between 8 and 40 (or up to 180 for ROCOF), compared to the C37.118 reference device. Steady-state frequency and ROCOF errors during sustained faults or unbalanced operation, particularly under unbalanced conditions, can be reduced by factors of hundreds or thousands compared to the C37.118 reference device.

KW - fourier transforms

KW - frequency measurement

KW - filtering algorithms

U2 - 10.1109/AMPS.2013.6656233

DO - 10.1109/AMPS.2013.6656233

M3 - Conference contribution book

SN - 978-1-4673-5571-1

SP - 97

EP - 102

BT - Proceedings of the 2013 IEEE International Workshop on Applied Measurements for Power Systems (AMPS)

PB - IEEE

ER -

Roscoe A, Burt G, Rietveld G. Improving frequency and ROCOF accuracy during faults, for P class Phasor Measurement Units. In Proceedings of the 2013 IEEE International Workshop on Applied Measurements for Power Systems (AMPS). IEEE. 2013. p. 97-102 https://doi.org/10.1109/AMPS.2013.6656233