TY - GEN
T1 - Impacts of air cavities on hygrothermal performance of retrofitted timber frame assemblies in six U.S. climates
AU - Recart, Carolina
AU - Sturts Dossick , Carrie
AU - Mendez Echenegucia, Tomas
PY - 2024/1/25
Y1 - 2024/1/25
N2 - Despite the growing interest in moisture behavior in buildings, building envelope designs rarely undergo assessment for hygrothermal control, especially when it comes to energy efficiency retrofits. Timber frame structures often incorporate a continuous air cavity that separates the exterior cladding from the wall sheathing. Indeed, using an air cavity increases thermal performance. To date, however, few studies have examined the impacts of air cavities on the hygrothermal performance in retrofitting projects. This study used WUFI Pro software to assess the influence of air cavities on the hygrothermal performance of existing building envelope components. We tested various ventilation rates for each wall assembly across six climates of the US. Findings show that adding an air cavity on the exterior side of the wall can reduce water accumulation during the simulation period. This element can prove especially beneficial in hot and humid climates since it increases dryness rates in the assembly.
AB - Despite the growing interest in moisture behavior in buildings, building envelope designs rarely undergo assessment for hygrothermal control, especially when it comes to energy efficiency retrofits. Timber frame structures often incorporate a continuous air cavity that separates the exterior cladding from the wall sheathing. Indeed, using an air cavity increases thermal performance. To date, however, few studies have examined the impacts of air cavities on the hygrothermal performance in retrofitting projects. This study used WUFI Pro software to assess the influence of air cavities on the hygrothermal performance of existing building envelope components. We tested various ventilation rates for each wall assembly across six climates of the US. Findings show that adding an air cavity on the exterior side of the wall can reduce water accumulation during the simulation period. This element can prove especially beneficial in hot and humid climates since it increases dryness rates in the assembly.
U2 - 10.1061/9780784485248.100
DO - 10.1061/9780784485248.100
M3 - Conference contribution book
BT - ASCE International Conference on Computing in Civil Engineering 2023
A2 - Turkan, Yelda
A2 - Louis, Joseph
A2 - Leite, Fernanda
A2 - Ergan, Semiha
T2 - ASCE International Conference on Computing in Civil Engineering 2023
Y2 - 25 June 2023 through 28 June 2023
ER -