Hydrodynamic performance analysis of the vertical axis twin-rotor tidal current turbine

Yong Ma, Chao Hu, Yulong Li, Lei Li, Rui Deng, Dapeng Jiang

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

The goal of this manuscript is to investigate the influence of relative distance between the twin rotors on the hydrodynamic performance of the vertical axis twin-rotor tidal current turbine. Computational fluid dynamics (CFD) simulations based on commercial software ANSYS-CFX have been performed to enhance the understanding of interactions between the twin-rotors. The interactions between the twin rotors are known to have increased the power output efficiency as a whole, and it is, therefore, of great significance to undertake deeper research. The simulation results are found to be consistent with similar research results in the literature in some aspects. The simulation results of stand-alone turbine and twin rotors are compared from three different aspects, including blade forces, power output efficiency and wake flow field. The results showed that the cyclic variations tendency of blade force coefficients of twin rotors is close to that of the stand-alone turbine. The average power output efficiency of the twin-rotors system is higher than that of the stand-alone turbine. The interactions between the turbines increase the power output of the twin turbine system as whole in a wide relative distance range. However, smaller relative distance between the twin rotors does not mean a bigger power output efficiency of such a system. The power out efficiency of such a system would decrease when the relative distance between the twin rotors exceeds the critical point. The power output of the twin rotors reaches the peak value when the ratio between the two main axis distance and diameter of the turbine is around 9/4. This research can provide a reference for the design and development of larger tidal power stations.

LanguageEnglish
Article number1694
Number of pages21
JournalWater
Volume10
Issue number11
DOIs
Publication statusPublished - 20 Nov 2018

Fingerprint

Turbines
Hydrodynamics
Rotors
Tidal power
Turbomachine blades
Flow fields
Computational fluid dynamics
Computer simulation

Keywords

  • computational fluid dynamics
  • interaction between turbines
  • power output efficiency
  • tidal current energy
  • vertical axis twin-turbine

Cite this

Ma, Y., Hu, C., Li, Y., Li, L., Deng, R., & Jiang, D. (2018). Hydrodynamic performance analysis of the vertical axis twin-rotor tidal current turbine. 10(11), [1694]. https://doi.org/10.3390/w10111694
Ma, Yong ; Hu, Chao ; Li, Yulong ; Li, Lei ; Deng, Rui ; Jiang, Dapeng. / Hydrodynamic performance analysis of the vertical axis twin-rotor tidal current turbine. 2018 ; Vol. 10, No. 11.
@article{d58657506f4247048142374f8fff8951,
title = "Hydrodynamic performance analysis of the vertical axis twin-rotor tidal current turbine",
abstract = "The goal of this manuscript is to investigate the influence of relative distance between the twin rotors on the hydrodynamic performance of the vertical axis twin-rotor tidal current turbine. Computational fluid dynamics (CFD) simulations based on commercial software ANSYS-CFX have been performed to enhance the understanding of interactions between the twin-rotors. The interactions between the twin rotors are known to have increased the power output efficiency as a whole, and it is, therefore, of great significance to undertake deeper research. The simulation results are found to be consistent with similar research results in the literature in some aspects. The simulation results of stand-alone turbine and twin rotors are compared from three different aspects, including blade forces, power output efficiency and wake flow field. The results showed that the cyclic variations tendency of blade force coefficients of twin rotors is close to that of the stand-alone turbine. The average power output efficiency of the twin-rotors system is higher than that of the stand-alone turbine. The interactions between the turbines increase the power output of the twin turbine system as whole in a wide relative distance range. However, smaller relative distance between the twin rotors does not mean a bigger power output efficiency of such a system. The power out efficiency of such a system would decrease when the relative distance between the twin rotors exceeds the critical point. The power output of the twin rotors reaches the peak value when the ratio between the two main axis distance and diameter of the turbine is around 9/4. This research can provide a reference for the design and development of larger tidal power stations.",
keywords = "computational fluid dynamics, interaction between turbines, power output efficiency, tidal current energy, vertical axis twin-turbine",
author = "Yong Ma and Chao Hu and Yulong Li and Lei Li and Rui Deng and Dapeng Jiang",
year = "2018",
month = "11",
day = "20",
doi = "10.3390/w10111694",
language = "English",
volume = "10",
number = "11",

}

Hydrodynamic performance analysis of the vertical axis twin-rotor tidal current turbine. / Ma, Yong; Hu, Chao; Li, Yulong; Li, Lei; Deng, Rui; Jiang, Dapeng.

Vol. 10, No. 11, 1694, 20.11.2018.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Hydrodynamic performance analysis of the vertical axis twin-rotor tidal current turbine

AU - Ma, Yong

AU - Hu, Chao

AU - Li, Yulong

AU - Li, Lei

AU - Deng, Rui

AU - Jiang, Dapeng

PY - 2018/11/20

Y1 - 2018/11/20

N2 - The goal of this manuscript is to investigate the influence of relative distance between the twin rotors on the hydrodynamic performance of the vertical axis twin-rotor tidal current turbine. Computational fluid dynamics (CFD) simulations based on commercial software ANSYS-CFX have been performed to enhance the understanding of interactions between the twin-rotors. The interactions between the twin rotors are known to have increased the power output efficiency as a whole, and it is, therefore, of great significance to undertake deeper research. The simulation results are found to be consistent with similar research results in the literature in some aspects. The simulation results of stand-alone turbine and twin rotors are compared from three different aspects, including blade forces, power output efficiency and wake flow field. The results showed that the cyclic variations tendency of blade force coefficients of twin rotors is close to that of the stand-alone turbine. The average power output efficiency of the twin-rotors system is higher than that of the stand-alone turbine. The interactions between the turbines increase the power output of the twin turbine system as whole in a wide relative distance range. However, smaller relative distance between the twin rotors does not mean a bigger power output efficiency of such a system. The power out efficiency of such a system would decrease when the relative distance between the twin rotors exceeds the critical point. The power output of the twin rotors reaches the peak value when the ratio between the two main axis distance and diameter of the turbine is around 9/4. This research can provide a reference for the design and development of larger tidal power stations.

AB - The goal of this manuscript is to investigate the influence of relative distance between the twin rotors on the hydrodynamic performance of the vertical axis twin-rotor tidal current turbine. Computational fluid dynamics (CFD) simulations based on commercial software ANSYS-CFX have been performed to enhance the understanding of interactions between the twin-rotors. The interactions between the twin rotors are known to have increased the power output efficiency as a whole, and it is, therefore, of great significance to undertake deeper research. The simulation results are found to be consistent with similar research results in the literature in some aspects. The simulation results of stand-alone turbine and twin rotors are compared from three different aspects, including blade forces, power output efficiency and wake flow field. The results showed that the cyclic variations tendency of blade force coefficients of twin rotors is close to that of the stand-alone turbine. The average power output efficiency of the twin-rotors system is higher than that of the stand-alone turbine. The interactions between the turbines increase the power output of the twin turbine system as whole in a wide relative distance range. However, smaller relative distance between the twin rotors does not mean a bigger power output efficiency of such a system. The power out efficiency of such a system would decrease when the relative distance between the twin rotors exceeds the critical point. The power output of the twin rotors reaches the peak value when the ratio between the two main axis distance and diameter of the turbine is around 9/4. This research can provide a reference for the design and development of larger tidal power stations.

KW - computational fluid dynamics

KW - interaction between turbines

KW - power output efficiency

KW - tidal current energy

KW - vertical axis twin-turbine

UR - http://www.scopus.com/inward/record.url?scp=85057015777&partnerID=8YFLogxK

UR - https://www.mdpi.com/journal/water

U2 - 10.3390/w10111694

DO - 10.3390/w10111694

M3 - Article

VL - 10

IS - 11

M1 - 1694

ER -