Abstract
A fast method is proposed for determining the oxygen gas-liquid diffusion coefficient from measurements of the fluorescence quenching behind a bubble. The approach consists of capturing pictures of the concentration field at micro-scale in the laminar bubble wake. The Gaussian concentration profiles measured in the wake are demonstrated to be systematically equivalent to an instantaneous plane diffusion case. The approach permits to accurately evaluate the gas-liquid diffusivity in a very short time of around one second. Since literature data on mass diffusion coefficients are actually not sufficient, a fast method is proposed to obtain oxygen diffusion coefficients from measuring the fluorescence quenching behind a bubble. Planar laser-induced fluorescence with inhibition presents a non-intrusive alternative method to accurately evaluate the gas-liquid diffusivity in a very short time.