Factors affecting solid-phase extraction of semi-volatile organic pollutants from acidic industrial effluent for analysis by gas chromatography

Iain S. Deans, Christine Davidson, David Littlejohn, Ian Brown

Research output: Contribution to journalArticle

18 Citations (Scopus)

Abstract

A method was developed for the solid-phase extraction of toluene, chlorobenzene, xylene, dichlorobenzene and trichlorobenzene from acidic, aqueous industrial effluent, prior to quantification by gas chromatography (GC). A variety of sorbent-solvent systems were investigated and the highest analyte recoveries were obtained with a C18 sorbent and chloroform. Dichloromethane can also be used as an alternative eluent. Up to 100 ml of effluent were passed through the cartridges, containing 500 mg of C18 sorbent, without degradation of the analyte recoveries. As the analytes were completely eluted with 1 ml of chloroform, preconcentration factors of up to 100-fold were achieved. To obtain close to quantitative (100%) recovery of the analytes from samples it is necessary to prevent evaporative losses which occur (a) during storage and sampling, if a headspace is created above the liquid, (b) when sorbent drying times >2 min are used and (c) if there is a significant delay (e.g., 45 min) between drying and elution of the analytes. Accordingly, each cartridge should be loaded and eluted in series to achieve maximum recoveries. The GC method detection limits (without preconcentration) were 0.18-0.33 mug ml-1, which are adequate for the determination of the analytes at concentrations typical of the effluent studied.

Original languageEnglish
Pages (from-to)1375-1382
Number of pages8
JournalAnalyst
Volume118
Issue number11
DOIs
Publication statusPublished - Nov 1993

Fingerprint

Organic pollutants
Solid Phase Extraction
Chloroform
Sorbents
organic pollutant
Gas chromatography
Gas Chromatography
Effluents
gas chromatography
Recovery
Xylenes
Methylene Chloride
Toluene
Chlorine compounds
chloroform
Limit of Detection
Drying
effluent
chlorobenzene
Dichloromethane

Keywords

  • solid-phase extraction
  • gas chromatography
  • aqueous industrial effluent

Cite this

@article{8a3d6e10e80c40f1a708641d4d8edf4b,
title = "Factors affecting solid-phase extraction of semi-volatile organic pollutants from acidic industrial effluent for analysis by gas chromatography",
abstract = "A method was developed for the solid-phase extraction of toluene, chlorobenzene, xylene, dichlorobenzene and trichlorobenzene from acidic, aqueous industrial effluent, prior to quantification by gas chromatography (GC). A variety of sorbent-solvent systems were investigated and the highest analyte recoveries were obtained with a C18 sorbent and chloroform. Dichloromethane can also be used as an alternative eluent. Up to 100 ml of effluent were passed through the cartridges, containing 500 mg of C18 sorbent, without degradation of the analyte recoveries. As the analytes were completely eluted with 1 ml of chloroform, preconcentration factors of up to 100-fold were achieved. To obtain close to quantitative (100{\%}) recovery of the analytes from samples it is necessary to prevent evaporative losses which occur (a) during storage and sampling, if a headspace is created above the liquid, (b) when sorbent drying times >2 min are used and (c) if there is a significant delay (e.g., 45 min) between drying and elution of the analytes. Accordingly, each cartridge should be loaded and eluted in series to achieve maximum recoveries. The GC method detection limits (without preconcentration) were 0.18-0.33 mug ml-1, which are adequate for the determination of the analytes at concentrations typical of the effluent studied.",
keywords = "solid-phase extraction, gas chromatography, aqueous industrial effluent",
author = "Deans, {Iain S.} and Christine Davidson and David Littlejohn and Ian Brown",
year = "1993",
month = "11",
doi = "10.1039/AN9931801375",
language = "English",
volume = "118",
pages = "1375--1382",
journal = "Analyst",
issn = "0003-2654",
number = "11",

}

Factors affecting solid-phase extraction of semi-volatile organic pollutants from acidic industrial effluent for analysis by gas chromatography. / Deans, Iain S.; Davidson, Christine; Littlejohn, David; Brown, Ian.

In: Analyst, Vol. 118, No. 11, 11.1993, p. 1375-1382.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Factors affecting solid-phase extraction of semi-volatile organic pollutants from acidic industrial effluent for analysis by gas chromatography

AU - Deans, Iain S.

AU - Davidson, Christine

AU - Littlejohn, David

AU - Brown, Ian

PY - 1993/11

Y1 - 1993/11

N2 - A method was developed for the solid-phase extraction of toluene, chlorobenzene, xylene, dichlorobenzene and trichlorobenzene from acidic, aqueous industrial effluent, prior to quantification by gas chromatography (GC). A variety of sorbent-solvent systems were investigated and the highest analyte recoveries were obtained with a C18 sorbent and chloroform. Dichloromethane can also be used as an alternative eluent. Up to 100 ml of effluent were passed through the cartridges, containing 500 mg of C18 sorbent, without degradation of the analyte recoveries. As the analytes were completely eluted with 1 ml of chloroform, preconcentration factors of up to 100-fold were achieved. To obtain close to quantitative (100%) recovery of the analytes from samples it is necessary to prevent evaporative losses which occur (a) during storage and sampling, if a headspace is created above the liquid, (b) when sorbent drying times >2 min are used and (c) if there is a significant delay (e.g., 45 min) between drying and elution of the analytes. Accordingly, each cartridge should be loaded and eluted in series to achieve maximum recoveries. The GC method detection limits (without preconcentration) were 0.18-0.33 mug ml-1, which are adequate for the determination of the analytes at concentrations typical of the effluent studied.

AB - A method was developed for the solid-phase extraction of toluene, chlorobenzene, xylene, dichlorobenzene and trichlorobenzene from acidic, aqueous industrial effluent, prior to quantification by gas chromatography (GC). A variety of sorbent-solvent systems were investigated and the highest analyte recoveries were obtained with a C18 sorbent and chloroform. Dichloromethane can also be used as an alternative eluent. Up to 100 ml of effluent were passed through the cartridges, containing 500 mg of C18 sorbent, without degradation of the analyte recoveries. As the analytes were completely eluted with 1 ml of chloroform, preconcentration factors of up to 100-fold were achieved. To obtain close to quantitative (100%) recovery of the analytes from samples it is necessary to prevent evaporative losses which occur (a) during storage and sampling, if a headspace is created above the liquid, (b) when sorbent drying times >2 min are used and (c) if there is a significant delay (e.g., 45 min) between drying and elution of the analytes. Accordingly, each cartridge should be loaded and eluted in series to achieve maximum recoveries. The GC method detection limits (without preconcentration) were 0.18-0.33 mug ml-1, which are adequate for the determination of the analytes at concentrations typical of the effluent studied.

KW - solid-phase extraction

KW - gas chromatography

KW - aqueous industrial effluent

U2 - 10.1039/AN9931801375

DO - 10.1039/AN9931801375

M3 - Article

VL - 118

SP - 1375

EP - 1382

JO - Analyst

JF - Analyst

SN - 0003-2654

IS - 11

ER -