TY - JOUR
T1 - Evaluation of the magnitude of hip joint deformation in subjects with avascular necrosis of the hip joint during walking with and without Scottish Rite orthosis
AU - Karimi, Mohammad Taghi
AU - Mohammadi, Ali
AU - Ebrahimi, Mohammad Hossein
AU - McGarry, Anthony
PY - 2017/2/28
Y1 - 2017/2/28
N2 - The femoral head in subjects with leg calve perthes disease (LCPD) is generally considerably deformed. It is debatable whether this deformation is due to an increase in applied loads, a decrease in bone mineral density or a change in containment of articular surfaces. The aim of this study was to determine the influence of these factors on deformation of the femoral head.
Two subjects with LCPD participated in this study. Subject motion and the forces applied on the affected leg were recorded using a motion analysis system (QualsisTM) and a Kistler force plate. OpenSim software was used to determine joint contact force of the hip joint whilst walking with and without a Scottish rite orthosis. 3D Models of hip joints of both subjects were produced by Mimics software. The deformation of femoral bone was determined by Abaqus.
Mean values of the force applied on the leg increased while walking with the orthosis. There was no difference between bone mineral density (BMD) of the femoral bone of normal and LCPD sides (p-value>0.05) and no difference between hip joint contact force of normal and LCPD sides. Hip joint containment appeared to decrease follow the use of the orthosis.
It can be concluded that the deformation of femoral head in LCPD may not be due to change in BMD or applied load. Although the Scottish rite orthosis is used mostly to increase hip joint containment, it appears to reduce hip joint contact area. It is recommended that a similar study is conducted using a higher number of subjects.
AB - The femoral head in subjects with leg calve perthes disease (LCPD) is generally considerably deformed. It is debatable whether this deformation is due to an increase in applied loads, a decrease in bone mineral density or a change in containment of articular surfaces. The aim of this study was to determine the influence of these factors on deformation of the femoral head.
Two subjects with LCPD participated in this study. Subject motion and the forces applied on the affected leg were recorded using a motion analysis system (QualsisTM) and a Kistler force plate. OpenSim software was used to determine joint contact force of the hip joint whilst walking with and without a Scottish rite orthosis. 3D Models of hip joints of both subjects were produced by Mimics software. The deformation of femoral bone was determined by Abaqus.
Mean values of the force applied on the leg increased while walking with the orthosis. There was no difference between bone mineral density (BMD) of the femoral bone of normal and LCPD sides (p-value>0.05) and no difference between hip joint contact force of normal and LCPD sides. Hip joint containment appeared to decrease follow the use of the orthosis.
It can be concluded that the deformation of femoral head in LCPD may not be due to change in BMD or applied load. Although the Scottish rite orthosis is used mostly to increase hip joint containment, it appears to reduce hip joint contact area. It is recommended that a similar study is conducted using a higher number of subjects.
KW - LCPD
KW - orthosis
KW - Scottish Rite
KW - walking
KW - joint contact force
KW - hip joint deformation
KW - leg calve perthes disease
KW - femoral head
KW - bone mineral density
UR - http://www.sciencedirect.com/science/journal/13504533
U2 - 10.1016/j.medengphy.2016.10.015
DO - 10.1016/j.medengphy.2016.10.015
M3 - Article
SN - 1350-4533
VL - 40
SP - 110
EP - 116
JO - Medical Engineering and Physics
JF - Medical Engineering and Physics
ER -