Empirical validation and modelling of a naturally ventilated rainscreen facade building

C. Marinosci, Paul Strachan, G. Semprini, G.L. Morini

Research output: Contribution to journalArticle

38 Citations (Scopus)

Abstract

In this paper the thermal behaviour of a rainscreen ventilated facade has been investigated both experimentally and numerically. Field measurements were performed during the 2009/10 winter season in a test building located in San Mauro Pascoli (Italy) having a squared base of internal dimension of 2.89 m and a total internal height of 7.75 m. The external walls of this tower are rainscreen ventilated facades with a 24 cm air cavity and an external side composed of stoneware with open joints. Ventilation grills are located at the top and at the bottom of the tower. In this work the modelling of the test building using a dynamic thermal simulation program (ESP-r) is presented and the main results discussed. In order to study the rainscreen ventilated facade three different multi-zone models were defined and the comparison with the experimental results has been used in order to select the best ESP-r air flow network for the modelling of this kind of envelope component. The thermal analysis of this envelope component evidenced that the ventilated facade is able to reverse the direction of the heat flux through the envelope in regions characterized by large solar irradiation during the winter and moderate wind velocity, when the indoor-outdoor air temperature difference is small, thereby reducing the energy consumption required for indoor heating.
LanguageEnglish
Pages853-863
Number of pages11
JournalEnergy and Buildings
Volume43
Issue number4
Early online date13 Dec 2010
DOIs
Publication statusPublished - Apr 2011

Fingerprint

Facades
Towers
Air
Thermoanalysis
Ventilation
Heat flux
Energy utilization
Irradiation
Heating
Temperature
Hot Temperature

Keywords

  • ventilated facade
  • test cell
  • modelling
  • rainscreen wall
  • simulation

Cite this

Marinosci, C. ; Strachan, Paul ; Semprini, G. ; Morini, G.L. / Empirical validation and modelling of a naturally ventilated rainscreen facade building. In: Energy and Buildings. 2011 ; Vol. 43, No. 4. pp. 853-863.
@article{f4b51f0fe3bb47d1be1e8026aea4d2a2,
title = "Empirical validation and modelling of a naturally ventilated rainscreen facade building",
abstract = "In this paper the thermal behaviour of a rainscreen ventilated facade has been investigated both experimentally and numerically. Field measurements were performed during the 2009/10 winter season in a test building located in San Mauro Pascoli (Italy) having a squared base of internal dimension of 2.89 m and a total internal height of 7.75 m. The external walls of this tower are rainscreen ventilated facades with a 24 cm air cavity and an external side composed of stoneware with open joints. Ventilation grills are located at the top and at the bottom of the tower. In this work the modelling of the test building using a dynamic thermal simulation program (ESP-r) is presented and the main results discussed. In order to study the rainscreen ventilated facade three different multi-zone models were defined and the comparison with the experimental results has been used in order to select the best ESP-r air flow network for the modelling of this kind of envelope component. The thermal analysis of this envelope component evidenced that the ventilated facade is able to reverse the direction of the heat flux through the envelope in regions characterized by large solar irradiation during the winter and moderate wind velocity, when the indoor-outdoor air temperature difference is small, thereby reducing the energy consumption required for indoor heating.",
keywords = "ventilated facade, test cell , modelling , rainscreen wall, simulation",
author = "C. Marinosci and Paul Strachan and G. Semprini and G.L. Morini",
year = "2011",
month = "4",
doi = "10.1016/j.enbuild.2010.12.005",
language = "English",
volume = "43",
pages = "853--863",
journal = "Energy and Buildings",
issn = "0378-7788",
publisher = "Elsevier BV",
number = "4",

}

Empirical validation and modelling of a naturally ventilated rainscreen facade building. / Marinosci, C.; Strachan, Paul; Semprini, G.; Morini, G.L.

In: Energy and Buildings, Vol. 43, No. 4, 04.2011, p. 853-863.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Empirical validation and modelling of a naturally ventilated rainscreen facade building

AU - Marinosci, C.

AU - Strachan, Paul

AU - Semprini, G.

AU - Morini, G.L.

PY - 2011/4

Y1 - 2011/4

N2 - In this paper the thermal behaviour of a rainscreen ventilated facade has been investigated both experimentally and numerically. Field measurements were performed during the 2009/10 winter season in a test building located in San Mauro Pascoli (Italy) having a squared base of internal dimension of 2.89 m and a total internal height of 7.75 m. The external walls of this tower are rainscreen ventilated facades with a 24 cm air cavity and an external side composed of stoneware with open joints. Ventilation grills are located at the top and at the bottom of the tower. In this work the modelling of the test building using a dynamic thermal simulation program (ESP-r) is presented and the main results discussed. In order to study the rainscreen ventilated facade three different multi-zone models were defined and the comparison with the experimental results has been used in order to select the best ESP-r air flow network for the modelling of this kind of envelope component. The thermal analysis of this envelope component evidenced that the ventilated facade is able to reverse the direction of the heat flux through the envelope in regions characterized by large solar irradiation during the winter and moderate wind velocity, when the indoor-outdoor air temperature difference is small, thereby reducing the energy consumption required for indoor heating.

AB - In this paper the thermal behaviour of a rainscreen ventilated facade has been investigated both experimentally and numerically. Field measurements were performed during the 2009/10 winter season in a test building located in San Mauro Pascoli (Italy) having a squared base of internal dimension of 2.89 m and a total internal height of 7.75 m. The external walls of this tower are rainscreen ventilated facades with a 24 cm air cavity and an external side composed of stoneware with open joints. Ventilation grills are located at the top and at the bottom of the tower. In this work the modelling of the test building using a dynamic thermal simulation program (ESP-r) is presented and the main results discussed. In order to study the rainscreen ventilated facade three different multi-zone models were defined and the comparison with the experimental results has been used in order to select the best ESP-r air flow network for the modelling of this kind of envelope component. The thermal analysis of this envelope component evidenced that the ventilated facade is able to reverse the direction of the heat flux through the envelope in regions characterized by large solar irradiation during the winter and moderate wind velocity, when the indoor-outdoor air temperature difference is small, thereby reducing the energy consumption required for indoor heating.

KW - ventilated facade

KW - test cell

KW - modelling

KW - rainscreen wall

KW - simulation

U2 - 10.1016/j.enbuild.2010.12.005

DO - 10.1016/j.enbuild.2010.12.005

M3 - Article

VL - 43

SP - 853

EP - 863

JO - Energy and Buildings

T2 - Energy and Buildings

JF - Energy and Buildings

SN - 0378-7788

IS - 4

ER -