Dynamic analysis of a pumped-storage hydropower plant with random power load

Hao Zhang, Diyi Chen, Beibei Xu, Edoardo Patelli, Silvia Tolo

Research output: Contribution to journalArticlepeer-review

39 Citations (Scopus)
39 Downloads (Pure)

Abstract

This paper analyzes the dynamic response of a pumped-storage hydropower plant in generating mode. Considering the elastic water column effects in the penstock, a linearized reduced order dynamic model of the pumped-storage hydropower plant is used in this paper. As the power load is always random, a set of random generator electric power output is introduced to research the dynamic behaviors of the pumped-storage hydropower plant. Then, the influences of the PI gains on the dynamic characteristics of the pumped-storage hydropower plant with the random power load are analyzed. In addition, the effects of initial power load and PI parameters on the stability of the pumped-storage hydropower plant are studied in depth. All of the above results will provide theoretical guidance for the study and analysis of the pumped-storage hydropower plant.
Original languageEnglish
Pages (from-to)524-533
Number of pages10
JournalMechanical Systems and Signal Processing
Volume100
Early online date5 Aug 2017
DOIs
Publication statusPublished - 1 Feb 2018

Keywords

  • pumped-storage hydropower plant
  • dynamic characteristics
  • random load
  • mathematical modeling

Fingerprint

Dive into the research topics of 'Dynamic analysis of a pumped-storage hydropower plant with random power load'. Together they form a unique fingerprint.

Cite this