Abstract
This paper analyzes the dynamic response of a pumped-storage hydropower plant in generating mode. Considering the elastic water column effects in the penstock, a linearized reduced order dynamic model of the pumped-storage hydropower plant is used in this paper. As the power load is always random, a set of random generator electric power output is introduced to research the dynamic behaviors of the pumped-storage hydropower plant. Then, the influences of the PI gains on the dynamic characteristics of the pumped-storage hydropower plant with the random power load are analyzed. In addition, the effects of initial power load and PI parameters on the stability of the pumped-storage hydropower plant are studied in depth. All of the above results will provide theoretical guidance for the study and analysis of the pumped-storage hydropower plant.
Original language | English |
---|---|
Pages (from-to) | 524-533 |
Number of pages | 10 |
Journal | Mechanical Systems and Signal Processing |
Volume | 100 |
Early online date | 5 Aug 2017 |
DOIs | |
Publication status | Published - 1 Feb 2018 |
Keywords
- pumped-storage hydropower plant
- dynamic characteristics
- random load
- mathematical modeling