Digital compensation method for high frequency current probes

Qingmin Li, W.H. Siew, Martin Stewart, Keith Walker, Chris Piner

Research output: Contribution to journalArticlepeer-review

3 Citations (Scopus)

Abstract

Based on the steepest descent theory (Edmonson W, Srinivasan K, Wang C and Principe J 1997 IEEE Trans. Circuits Syst.45 379-84, Neil E and Mian O N 1992 IEEE Trans. Neural Netw.3 308-14) and the original response curve of a current probe used for power system electromagnetic compatibility measurement, an accurate analogue model has been built for the probe, with a maximum error of 5.2%. Before application the analogue model needs to be discretized in the z domain, however the digital model gives a steeper frequency response than the analogue one. To compensate for this effect, another digital band-pass filter was attached to the above model, and its parameters were obtained by computer simulation. The compensated digital model presented a maximum error of 5.8% compared with the probe's response curve. The digital modelling and compensating strategy can feasibly expand the frequency band over which the probe is useful for measurement applications.
Original languageEnglish
Pages (from-to)529-532
Number of pages3
JournalMeasurement Science and Technology
Volume13
Issue number4
DOIs
Publication statusPublished - 2002

Keywords

  • digital modelling
  • steepest descent algorithms
  • filtering
  • steepest descent theory

Fingerprint Dive into the research topics of 'Digital compensation method for high frequency current probes'. Together they form a unique fingerprint.

Cite this