Abstract
Language | English |
---|---|
Publication status | Published - Sep 2007 |
Event | International Building Performance Simulation Association (IBPSA) Conference 2007 - Beijing, China Duration: 3 Sep 2007 → 6 Sep 2007 |
Conference
Conference | International Building Performance Simulation Association (IBPSA) Conference 2007 |
---|---|
City | Beijing, China |
Period | 3/09/07 → 6/09/07 |
Fingerprint
Keywords
- modeling
- ground heat exchanger
- simulations
- test cases
- heat pumps
Cite this
}
Development and application of test cases for comparing vertical ground heat exchanger models. / Bernier, M.; Kummert, M.; Bertagnolio, S.
2007. Paper presented at International Building Performance Simulation Association (IBPSA) Conference 2007, Beijing, China, .Research output: Contribution to conference › Paper
TY - CONF
T1 - Development and application of test cases for comparing vertical ground heat exchanger models
AU - Bernier, M.
AU - Kummert, M.
AU - Bertagnolio, S.
PY - 2007/9
Y1 - 2007/9
N2 - The main objective of this paper is to establish a set of test cases for analytical verifications and intermodel comparisons of ground heat exchanger (GHX) models used in building simulation programs. Several test cases are suggested. They range from steady-state heat rejection in a single borehole to varying hourly loads with large yearly thermal imbalance in multiple borehole configurations. The usefulness of the proposed test cases is illustrated by running them with different GHX models. This comparison exercise has shown that 1-D models compare favourably well with the more elaborate 3-D models for relatively small simulation periods. The cyclic heat rejection/collection test has revealed some small deficiency in the load aggregation scheme of a particular model. Finally, the use of the asymmetric (cooling-dominated) load profile test case for a bore field composed of 100 boreholes revealed that the borehole wall temperature predicted by two GHX models can differ by as much as 10oC after a 30 year simulation.
AB - The main objective of this paper is to establish a set of test cases for analytical verifications and intermodel comparisons of ground heat exchanger (GHX) models used in building simulation programs. Several test cases are suggested. They range from steady-state heat rejection in a single borehole to varying hourly loads with large yearly thermal imbalance in multiple borehole configurations. The usefulness of the proposed test cases is illustrated by running them with different GHX models. This comparison exercise has shown that 1-D models compare favourably well with the more elaborate 3-D models for relatively small simulation periods. The cyclic heat rejection/collection test has revealed some small deficiency in the load aggregation scheme of a particular model. Finally, the use of the asymmetric (cooling-dominated) load profile test case for a bore field composed of 100 boreholes revealed that the borehole wall temperature predicted by two GHX models can differ by as much as 10oC after a 30 year simulation.
KW - modeling
KW - ground heat exchanger
KW - simulations
KW - test cases
KW - heat pumps
UR - http://www.ibpsa.org/m_papers.asp
UR - http://www.mecheng.strath.ac.uk/staffprofile.asp?id=137
UR - http://www.ibpsa.org/proceedings/BS2007/p500_final.pdf
M3 - Paper
ER -