Developing and testing a generic micro-combined heat and power model for simulations of dwellings and highly distributed power systems

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

This paper elaborates an approach to the modelling of domestic micro-combined heat and power (μ-CHP) using a building simulation tool that can provide a detailed picture of the environmental performance of both the μ-CHP heating system and the dwelling it serves. The approach can also provide useful data for the modelling of highly distributed power systems (HDPS). At the commencement of the work described in this paper no μ-CHP device model that was compatible with a building simulation tool was available. The development of such a model is described along with its calibration and verification. The simulation tool with the device model was then applied to the analysis of a dwelling with a Stirling engine-based heating system. Different levels of thermal insulation and occupancy types were modelled. The energy and environmental performance of the μ-CHP device was quantified for each case; additionally, the potential for its participation in the control and operation of an HDPS was assessed. Analysis of the simulation results indicated that the parasitic losses associated with the μ-CHP system balance of plant reduced the overall heating system efficiency by up to 40 per cent. Performance deteriorated with increasing levels of insulation in the dwelling, resulting in reduced thermal efficiency and increased cycling, though overall fuel use was reduced. The analysis also indicated that the device was generally available to participate in HDPS control for greater than 90 per cent of the simulation time. The potential length of the participation time ranged from 1 to 800+min and depended upon the state of the μ-CHP system thermal buffer and prevailing heat loads. Probabilities for different participation times and modes were calculated.
LanguageEnglish
Pages685-695
Number of pages11
JournalProceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
Volume222
Issue number7
DOIs
Publication statusPublished - 1 Nov 2008

Fingerprint

Heating
Testing
Stirling engines
Thermal insulation
Thermal load
Insulation
Calibration
Control systems
Hot Temperature

Keywords

  • micro-combined heat and power
  • building simulation model
  • highly distributed power system

Cite this

@article{cfbe155041244ea2b123ef64a75cc4ba,
title = "Developing and testing a generic micro-combined heat and power model for simulations of dwellings and highly distributed power systems",
abstract = "This paper elaborates an approach to the modelling of domestic micro-combined heat and power (μ-CHP) using a building simulation tool that can provide a detailed picture of the environmental performance of both the μ-CHP heating system and the dwelling it serves. The approach can also provide useful data for the modelling of highly distributed power systems (HDPS). At the commencement of the work described in this paper no μ-CHP device model that was compatible with a building simulation tool was available. The development of such a model is described along with its calibration and verification. The simulation tool with the device model was then applied to the analysis of a dwelling with a Stirling engine-based heating system. Different levels of thermal insulation and occupancy types were modelled. The energy and environmental performance of the μ-CHP device was quantified for each case; additionally, the potential for its participation in the control and operation of an HDPS was assessed. Analysis of the simulation results indicated that the parasitic losses associated with the μ-CHP system balance of plant reduced the overall heating system efficiency by up to 40 per cent. Performance deteriorated with increasing levels of insulation in the dwelling, resulting in reduced thermal efficiency and increased cycling, though overall fuel use was reduced. The analysis also indicated that the device was generally available to participate in HDPS control for greater than 90 per cent of the simulation time. The potential length of the participation time ranged from 1 to 800+min and depended upon the state of the μ-CHP system thermal buffer and prevailing heat loads. Probabilities for different participation times and modes were calculated.",
keywords = "micro-combined heat and power, building simulation model, highly distributed power system",
author = "N.J. Kelly and J.A. Clarke and A. Ferguson and G. Burt",
year = "2008",
month = "11",
day = "1",
doi = "10.1243/09576509JPE532",
language = "English",
volume = "222",
pages = "685--695",
journal = "Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy",
issn = "0957-6509",
number = "7",

}

TY - JOUR

T1 - Developing and testing a generic micro-combined heat and power model for simulations of dwellings and highly distributed power systems

AU - Kelly, N.J.

AU - Clarke, J.A.

AU - Ferguson, A.

AU - Burt, G.

PY - 2008/11/1

Y1 - 2008/11/1

N2 - This paper elaborates an approach to the modelling of domestic micro-combined heat and power (μ-CHP) using a building simulation tool that can provide a detailed picture of the environmental performance of both the μ-CHP heating system and the dwelling it serves. The approach can also provide useful data for the modelling of highly distributed power systems (HDPS). At the commencement of the work described in this paper no μ-CHP device model that was compatible with a building simulation tool was available. The development of such a model is described along with its calibration and verification. The simulation tool with the device model was then applied to the analysis of a dwelling with a Stirling engine-based heating system. Different levels of thermal insulation and occupancy types were modelled. The energy and environmental performance of the μ-CHP device was quantified for each case; additionally, the potential for its participation in the control and operation of an HDPS was assessed. Analysis of the simulation results indicated that the parasitic losses associated with the μ-CHP system balance of plant reduced the overall heating system efficiency by up to 40 per cent. Performance deteriorated with increasing levels of insulation in the dwelling, resulting in reduced thermal efficiency and increased cycling, though overall fuel use was reduced. The analysis also indicated that the device was generally available to participate in HDPS control for greater than 90 per cent of the simulation time. The potential length of the participation time ranged from 1 to 800+min and depended upon the state of the μ-CHP system thermal buffer and prevailing heat loads. Probabilities for different participation times and modes were calculated.

AB - This paper elaborates an approach to the modelling of domestic micro-combined heat and power (μ-CHP) using a building simulation tool that can provide a detailed picture of the environmental performance of both the μ-CHP heating system and the dwelling it serves. The approach can also provide useful data for the modelling of highly distributed power systems (HDPS). At the commencement of the work described in this paper no μ-CHP device model that was compatible with a building simulation tool was available. The development of such a model is described along with its calibration and verification. The simulation tool with the device model was then applied to the analysis of a dwelling with a Stirling engine-based heating system. Different levels of thermal insulation and occupancy types were modelled. The energy and environmental performance of the μ-CHP device was quantified for each case; additionally, the potential for its participation in the control and operation of an HDPS was assessed. Analysis of the simulation results indicated that the parasitic losses associated with the μ-CHP system balance of plant reduced the overall heating system efficiency by up to 40 per cent. Performance deteriorated with increasing levels of insulation in the dwelling, resulting in reduced thermal efficiency and increased cycling, though overall fuel use was reduced. The analysis also indicated that the device was generally available to participate in HDPS control for greater than 90 per cent of the simulation time. The potential length of the participation time ranged from 1 to 800+min and depended upon the state of the μ-CHP system thermal buffer and prevailing heat loads. Probabilities for different participation times and modes were calculated.

KW - micro-combined heat and power

KW - building simulation model

KW - highly distributed power system

U2 - 10.1243/09576509JPE532

DO - 10.1243/09576509JPE532

M3 - Article

VL - 222

SP - 685

EP - 695

JO - Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy

T2 - Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy

JF - Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy

SN - 0957-6509

IS - 7

ER -