Controlling the variable of pressure in the production of test footwear impressions

Kevin Farrugia, Philip Riches, H. Bandey, Kathleen Savage, Niamh Nic Daeid

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Footwear impression lifting and enhancement techniques may be affected by several variables introduced during the production of test footwear impressions, thus limiting the usefulness of enhancement technique comparisons and the results obtained. One such variable is the force applied when the impressed mark is being made. Producing consistent test impressions for research into footwear enhancement techniques would therefore be beneficial. This study was designed to control pressure in the production of test footwear impressions when mimicking a stamping action. Twenty-seven volunteers were asked to stamp on two different surfaces and the average stamping force was recorded. Information from the data obtained was used to design and build a mechanical device which could be calibrated to consistently deliver footwear impressions with the same force onto a receiving surface. Preliminary experiments using this device and different contaminants on the footwear sole have yielded consistent and repeatable impressions. Controlling the variable of pressure for the production of test impressions in this study demonstrated that the differences observed were visual (due to the amount of contaminant transferred and subsequent enhancement) and did not affect the replication of outer sole characteristics. This paper reports the development of the device and illustrates the quality of the impressions produced.
LanguageEnglish
Pages168–176
Number of pages9
JournalScience and Justice
Volume52
Issue number3
Early online date22 Dec 2011
DOIs
Publication statusPublished - Sep 2012

Fingerprint

Pressure
Equipment and Supplies
Volunteers
Research

Keywords

  • footwear impressions
  • luminol
  • acid yellow 7
  • blood
  • stamping

Cite this

Farrugia, Kevin ; Riches, Philip ; Bandey, H. ; Savage, Kathleen ; Nic Daeid, Niamh. / Controlling the variable of pressure in the production of test footwear impressions. In: Science and Justice. 2012 ; Vol. 52, No. 3. pp. 168–176.
@article{cdfd5edb4fcf4ecc9b4d5d10eee4ed25,
title = "Controlling the variable of pressure in the production of test footwear impressions",
abstract = "Footwear impression lifting and enhancement techniques may be affected by several variables introduced during the production of test footwear impressions, thus limiting the usefulness of enhancement technique comparisons and the results obtained. One such variable is the force applied when the impressed mark is being made. Producing consistent test impressions for research into footwear enhancement techniques would therefore be beneficial. This study was designed to control pressure in the production of test footwear impressions when mimicking a stamping action. Twenty-seven volunteers were asked to stamp on two different surfaces and the average stamping force was recorded. Information from the data obtained was used to design and build a mechanical device which could be calibrated to consistently deliver footwear impressions with the same force onto a receiving surface. Preliminary experiments using this device and different contaminants on the footwear sole have yielded consistent and repeatable impressions. Controlling the variable of pressure for the production of test impressions in this study demonstrated that the differences observed were visual (due to the amount of contaminant transferred and subsequent enhancement) and did not affect the replication of outer sole characteristics. This paper reports the development of the device and illustrates the quality of the impressions produced.",
keywords = "footwear impressions , luminol, acid yellow 7 , blood , stamping",
author = "Kevin Farrugia and Philip Riches and H. Bandey and Kathleen Savage and {Nic Daeid}, Niamh",
year = "2012",
month = "9",
doi = "10.1016/j.scijus.2011.11.002",
language = "English",
volume = "52",
pages = "168–176",
journal = "Science and Justice",
issn = "1355-0306",
number = "3",

}

Controlling the variable of pressure in the production of test footwear impressions. / Farrugia, Kevin; Riches, Philip; Bandey, H.; Savage, Kathleen; Nic Daeid, Niamh.

In: Science and Justice, Vol. 52, No. 3, 09.2012, p. 168–176.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Controlling the variable of pressure in the production of test footwear impressions

AU - Farrugia, Kevin

AU - Riches, Philip

AU - Bandey, H.

AU - Savage, Kathleen

AU - Nic Daeid, Niamh

PY - 2012/9

Y1 - 2012/9

N2 - Footwear impression lifting and enhancement techniques may be affected by several variables introduced during the production of test footwear impressions, thus limiting the usefulness of enhancement technique comparisons and the results obtained. One such variable is the force applied when the impressed mark is being made. Producing consistent test impressions for research into footwear enhancement techniques would therefore be beneficial. This study was designed to control pressure in the production of test footwear impressions when mimicking a stamping action. Twenty-seven volunteers were asked to stamp on two different surfaces and the average stamping force was recorded. Information from the data obtained was used to design and build a mechanical device which could be calibrated to consistently deliver footwear impressions with the same force onto a receiving surface. Preliminary experiments using this device and different contaminants on the footwear sole have yielded consistent and repeatable impressions. Controlling the variable of pressure for the production of test impressions in this study demonstrated that the differences observed were visual (due to the amount of contaminant transferred and subsequent enhancement) and did not affect the replication of outer sole characteristics. This paper reports the development of the device and illustrates the quality of the impressions produced.

AB - Footwear impression lifting and enhancement techniques may be affected by several variables introduced during the production of test footwear impressions, thus limiting the usefulness of enhancement technique comparisons and the results obtained. One such variable is the force applied when the impressed mark is being made. Producing consistent test impressions for research into footwear enhancement techniques would therefore be beneficial. This study was designed to control pressure in the production of test footwear impressions when mimicking a stamping action. Twenty-seven volunteers were asked to stamp on two different surfaces and the average stamping force was recorded. Information from the data obtained was used to design and build a mechanical device which could be calibrated to consistently deliver footwear impressions with the same force onto a receiving surface. Preliminary experiments using this device and different contaminants on the footwear sole have yielded consistent and repeatable impressions. Controlling the variable of pressure for the production of test impressions in this study demonstrated that the differences observed were visual (due to the amount of contaminant transferred and subsequent enhancement) and did not affect the replication of outer sole characteristics. This paper reports the development of the device and illustrates the quality of the impressions produced.

KW - footwear impressions

KW - luminol

KW - acid yellow 7

KW - blood

KW - stamping

UR - http://www.scopus.com/inward/record.url?scp=84864293096&partnerID=8YFLogxK

U2 - 10.1016/j.scijus.2011.11.002

DO - 10.1016/j.scijus.2011.11.002

M3 - Article

VL - 52

SP - 168

EP - 176

JO - Science and Justice

T2 - Science and Justice

JF - Science and Justice

SN - 1355-0306

IS - 3

ER -