Cadence, energy expenditure, and gait symmetry during music-prompted and self-regulated walking in adults with unilateral transtibial amputation

David A. Rowe, David McMinn, Leslie Peacock, Adrianus W. P. Buis, Rona Sutherland, Emma Henderson, Allan Hewitt

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

Walking cadence has shown promise for estimating walking intensity in healthy adults. Auditory cues have been shown to improve gait symmetry in populations with movement disorders. We investigated the walking cadence-energy expenditure relationship in unilateral transtibial amputees (TTAs), and the potential of music cues for regulating walking cadence and improving gait symmetry. Seventeen unilateral TTAs performed two 5-min treadmill walking trials, followed by two 5-min overground walking trials (self-regulated “brisk” intensity, and while attempting to match a moderate-tempo digital music cue). Walking cadence significantly (P<.001) and accurately (R2=.55, SEE=0.50 METs) predicted energy expenditure, and a cadence of 86 steps·min-1 was equivalent to a 3-MET intensity. Although most participants were able to match cadence to prescribed music tempo, gait symmetry was not improved during the music-guided condition, compared to the self-regulated condition. This is the first study to investigate the utility of walking cadence for monitoring and regulating walking intensity in adults with lower limb prosthesis. Cadence has similar or superior accuracy as an indicator of walking intensity in this population, compared to the general population, and adults with a unilateral TTA are capable of walking at moderate intensity and above for meaningful bouts of time.
LanguageEnglish
Pages320-329
Number of pages10
JournalJournal of Physical Activity and Health
Volume11
Issue number2
DOIs
Publication statusPublished - 28 Feb 2014

Fingerprint

Music
Gait
Amputation
Energy Metabolism
Walking
Amputees
Cues
Population
Movement Disorders
Prostheses and Implants
Lower Extremity

Keywords

  • physical activity
  • gait analysis
  • transtibial amputee

Cite this

@article{6bd61813ad6a48cd9801a6f130b15fd3,
title = "Cadence, energy expenditure, and gait symmetry during music-prompted and self-regulated walking in adults with unilateral transtibial amputation",
abstract = "Walking cadence has shown promise for estimating walking intensity in healthy adults. Auditory cues have been shown to improve gait symmetry in populations with movement disorders. We investigated the walking cadence-energy expenditure relationship in unilateral transtibial amputees (TTAs), and the potential of music cues for regulating walking cadence and improving gait symmetry. Seventeen unilateral TTAs performed two 5-min treadmill walking trials, followed by two 5-min overground walking trials (self-regulated “brisk” intensity, and while attempting to match a moderate-tempo digital music cue). Walking cadence significantly (P<.001) and accurately (R2=.55, SEE=0.50 METs) predicted energy expenditure, and a cadence of 86 steps·min-1 was equivalent to a 3-MET intensity. Although most participants were able to match cadence to prescribed music tempo, gait symmetry was not improved during the music-guided condition, compared to the self-regulated condition. This is the first study to investigate the utility of walking cadence for monitoring and regulating walking intensity in adults with lower limb prosthesis. Cadence has similar or superior accuracy as an indicator of walking intensity in this population, compared to the general population, and adults with a unilateral TTA are capable of walking at moderate intensity and above for meaningful bouts of time.",
keywords = "physical activity, gait analysis, transtibial amputee",
author = "Rowe, {David A.} and David McMinn and Leslie Peacock and Buis, {Adrianus W. P.} and Rona Sutherland and Emma Henderson and Allan Hewitt",
year = "2014",
month = "2",
day = "28",
doi = "10.1123/jpah.2012-0056",
language = "English",
volume = "11",
pages = "320--329",
journal = "Journal of Physical Activity and Health",
issn = "1543-3080",
number = "2",

}

Cadence, energy expenditure, and gait symmetry during music-prompted and self-regulated walking in adults with unilateral transtibial amputation. / Rowe, David A.; McMinn, David; Peacock, Leslie; Buis, Adrianus W. P.; Sutherland, Rona; Henderson, Emma; Hewitt, Allan.

In: Journal of Physical Activity and Health, Vol. 11, No. 2, 28.02.2014, p. 320-329.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Cadence, energy expenditure, and gait symmetry during music-prompted and self-regulated walking in adults with unilateral transtibial amputation

AU - Rowe, David A.

AU - McMinn, David

AU - Peacock, Leslie

AU - Buis, Adrianus W. P.

AU - Sutherland, Rona

AU - Henderson, Emma

AU - Hewitt, Allan

PY - 2014/2/28

Y1 - 2014/2/28

N2 - Walking cadence has shown promise for estimating walking intensity in healthy adults. Auditory cues have been shown to improve gait symmetry in populations with movement disorders. We investigated the walking cadence-energy expenditure relationship in unilateral transtibial amputees (TTAs), and the potential of music cues for regulating walking cadence and improving gait symmetry. Seventeen unilateral TTAs performed two 5-min treadmill walking trials, followed by two 5-min overground walking trials (self-regulated “brisk” intensity, and while attempting to match a moderate-tempo digital music cue). Walking cadence significantly (P<.001) and accurately (R2=.55, SEE=0.50 METs) predicted energy expenditure, and a cadence of 86 steps·min-1 was equivalent to a 3-MET intensity. Although most participants were able to match cadence to prescribed music tempo, gait symmetry was not improved during the music-guided condition, compared to the self-regulated condition. This is the first study to investigate the utility of walking cadence for monitoring and regulating walking intensity in adults with lower limb prosthesis. Cadence has similar or superior accuracy as an indicator of walking intensity in this population, compared to the general population, and adults with a unilateral TTA are capable of walking at moderate intensity and above for meaningful bouts of time.

AB - Walking cadence has shown promise for estimating walking intensity in healthy adults. Auditory cues have been shown to improve gait symmetry in populations with movement disorders. We investigated the walking cadence-energy expenditure relationship in unilateral transtibial amputees (TTAs), and the potential of music cues for regulating walking cadence and improving gait symmetry. Seventeen unilateral TTAs performed two 5-min treadmill walking trials, followed by two 5-min overground walking trials (self-regulated “brisk” intensity, and while attempting to match a moderate-tempo digital music cue). Walking cadence significantly (P<.001) and accurately (R2=.55, SEE=0.50 METs) predicted energy expenditure, and a cadence of 86 steps·min-1 was equivalent to a 3-MET intensity. Although most participants were able to match cadence to prescribed music tempo, gait symmetry was not improved during the music-guided condition, compared to the self-regulated condition. This is the first study to investigate the utility of walking cadence for monitoring and regulating walking intensity in adults with lower limb prosthesis. Cadence has similar or superior accuracy as an indicator of walking intensity in this population, compared to the general population, and adults with a unilateral TTA are capable of walking at moderate intensity and above for meaningful bouts of time.

KW - physical activity

KW - gait analysis

KW - transtibial amputee

UR - http://journals.humankinetics.com/jpah-in-press/jpah-in-press/cadence-energy-expenditure-and-gait-symmetry-during-music-prompted-and-self-regulated-walking-in-adults-with-unilateral-transtibial-amputation

U2 - 10.1123/jpah.2012-0056

DO - 10.1123/jpah.2012-0056

M3 - Article

VL - 11

SP - 320

EP - 329

JO - Journal of Physical Activity and Health

T2 - Journal of Physical Activity and Health

JF - Journal of Physical Activity and Health

SN - 1543-3080

IS - 2

ER -