Assessment of the reliability of loss of mains protection incorporating satellite communications

Ahmed Adnan Makki, Adam Dysko, Martin Lee, William Hung

Research output: Chapter in Book/Report/Conference proceedingConference contribution book

1 Citation (Scopus)

Abstract

This paper builds upon the earlier research which proposed the use of satellite communication media to achieve improved performance of the Loss-Of-Mains (LOM) protection by eliminating nuisance tripping and ensuring reliable islanding detection. The focus of this paper is the practical development of the laboratory based trial of the satellite based LOM protection and the experimental assessment of the performance of such protection scheme.
LanguageEnglish
Title of host publication11th international conference on developments in power systems protection, 2012. DPSP 2012.
Place of PublicationNew York
PublisherIEEE
Number of pages6
ISBN (Print)9781849196208
DOIs
Publication statusPublished - 23 Apr 2012
EventIET DPSP: Developments in Power System Protection 2012 - Birmingham, United Kingdom
Duration: 23 Apr 201226 Apr 2012

Conference

ConferenceIET DPSP: Developments in Power System Protection 2012
CountryUnited Kingdom
CityBirmingham
Period23/04/1226/04/12

Fingerprint

Communication satellites
Satellites

Keywords

  • reliability assessment
  • loss of mains protection
  • satellite communications
  • power system protection
  • loss-of-mains
  • LOM
  • distributed generations

Cite this

Makki, A. A., Dysko, A., Lee, M., & Hung, W. (2012). Assessment of the reliability of loss of mains protection incorporating satellite communications. In 11th international conference on developments in power systems protection, 2012. DPSP 2012. New York: IEEE. https://doi.org/10.1049/cp.2012.0029
Makki, Ahmed Adnan ; Dysko, Adam ; Lee, Martin ; Hung, William. / Assessment of the reliability of loss of mains protection incorporating satellite communications. 11th international conference on developments in power systems protection, 2012. DPSP 2012. . New York : IEEE, 2012.
@inproceedings{d01924b85b064829bad40a046a682757,
title = "Assessment of the reliability of loss of mains protection incorporating satellite communications",
abstract = "This paper builds upon the earlier research which proposed the use of satellite communication media to achieve improved performance of the Loss-Of-Mains (LOM) protection by eliminating nuisance tripping and ensuring reliable islanding detection. The focus of this paper is the practical development of the laboratory based trial of the satellite based LOM protection and the experimental assessment of the performance of such protection scheme.",
keywords = "reliability assessment, loss of mains protection, satellite communications, power system protection, loss-of-mains , LOM, distributed generations",
author = "Makki, {Ahmed Adnan} and Adam Dysko and Martin Lee and William Hung",
year = "2012",
month = "4",
day = "23",
doi = "10.1049/cp.2012.0029",
language = "English",
isbn = "9781849196208",
booktitle = "11th international conference on developments in power systems protection, 2012. DPSP 2012.",
publisher = "IEEE",

}

Makki, AA, Dysko, A, Lee, M & Hung, W 2012, Assessment of the reliability of loss of mains protection incorporating satellite communications. in 11th international conference on developments in power systems protection, 2012. DPSP 2012. . IEEE, New York, IET DPSP: Developments in Power System Protection 2012, Birmingham, United Kingdom, 23/04/12. https://doi.org/10.1049/cp.2012.0029

Assessment of the reliability of loss of mains protection incorporating satellite communications. / Makki, Ahmed Adnan; Dysko, Adam; Lee, Martin; Hung, William.

11th international conference on developments in power systems protection, 2012. DPSP 2012. . New York : IEEE, 2012.

Research output: Chapter in Book/Report/Conference proceedingConference contribution book

TY - GEN

T1 - Assessment of the reliability of loss of mains protection incorporating satellite communications

AU - Makki, Ahmed Adnan

AU - Dysko, Adam

AU - Lee, Martin

AU - Hung, William

PY - 2012/4/23

Y1 - 2012/4/23

N2 - This paper builds upon the earlier research which proposed the use of satellite communication media to achieve improved performance of the Loss-Of-Mains (LOM) protection by eliminating nuisance tripping and ensuring reliable islanding detection. The focus of this paper is the practical development of the laboratory based trial of the satellite based LOM protection and the experimental assessment of the performance of such protection scheme.

AB - This paper builds upon the earlier research which proposed the use of satellite communication media to achieve improved performance of the Loss-Of-Mains (LOM) protection by eliminating nuisance tripping and ensuring reliable islanding detection. The focus of this paper is the practical development of the laboratory based trial of the satellite based LOM protection and the experimental assessment of the performance of such protection scheme.

KW - reliability assessment

KW - loss of mains protection

KW - satellite communications

KW - power system protection

KW - loss-of-mains

KW - LOM

KW - distributed generations

UR - http://www.scopus.com/inward/record.url?scp=84863648315&partnerID=8YFLogxK

UR - http://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6227515

U2 - 10.1049/cp.2012.0029

DO - 10.1049/cp.2012.0029

M3 - Conference contribution book

SN - 9781849196208

BT - 11th international conference on developments in power systems protection, 2012. DPSP 2012.

PB - IEEE

CY - New York

ER -

Makki AA, Dysko A, Lee M, Hung W. Assessment of the reliability of loss of mains protection incorporating satellite communications. In 11th international conference on developments in power systems protection, 2012. DPSP 2012. . New York: IEEE. 2012 https://doi.org/10.1049/cp.2012.0029