Anti-Acanthamoeba efficacy in contact lens disinfecting systems

T.K. Beattie, A. Tomlinson, D. Seal

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

Hiti et al produced an interesting study investigating the susceptibility of three strains of Acanthamoeba to a PHMB (polyhexamethylene biguanide) based multipurpose solution (MPS), a one step peroxide system (3% H2O2), and a two step peroxide system (0.6% H2O2). However, no comment was made regarding the choice of strains tested, only one of which (A castellanii 4CL) was typical of those that cause keratitis in humans. Although testing of all three strains was of interest to the microbiologist, the only result that can be extrapolated to clinical practice and be of clinical relevance to the contact lens wearer is that for A castellanii (4CL).
LanguageEnglish
Pages1310-1320
Number of pages10
JournalBritish Journal of Ophthalmology
Volume86
Issue number11
Publication statusPublished - Nov 2002

Fingerprint

Acanthamoeba
Contact Lenses
Peroxides
Keratitis
polyhexamethylene biguanide

Keywords

  • contact lens disinfecting systems
  • Acanthamoeba
  • A castellanii 4CL

Cite this

Beattie, T.K. ; Tomlinson, A. ; Seal, D. / Anti-Acanthamoeba efficacy in contact lens disinfecting systems. In: British Journal of Ophthalmology. 2002 ; Vol. 86, No. 11. pp. 1310-1320.
@article{4fdc8c7176fd49358c3e76892d014097,
title = "Anti-Acanthamoeba efficacy in contact lens disinfecting systems",
abstract = "Hiti et al produced an interesting study investigating the susceptibility of three strains of Acanthamoeba to a PHMB (polyhexamethylene biguanide) based multipurpose solution (MPS), a one step peroxide system (3{\%} H2O2), and a two step peroxide system (0.6{\%} H2O2). However, no comment was made regarding the choice of strains tested, only one of which (A castellanii 4CL) was typical of those that cause keratitis in humans. Although testing of all three strains was of interest to the microbiologist, the only result that can be extrapolated to clinical practice and be of clinical relevance to the contact lens wearer is that for A castellanii (4CL).",
keywords = "contact lens disinfecting systems, Acanthamoeba, A castellanii 4CL",
author = "T.K. Beattie and A. Tomlinson and D. Seal",
year = "2002",
month = "11",
language = "English",
volume = "86",
pages = "1310--1320",
journal = "British Journal of Ophthalmology",
issn = "0007-1161",
number = "11",

}

Anti-Acanthamoeba efficacy in contact lens disinfecting systems. / Beattie, T.K.; Tomlinson, A.; Seal, D.

In: British Journal of Ophthalmology, Vol. 86, No. 11, 11.2002, p. 1310-1320.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Anti-Acanthamoeba efficacy in contact lens disinfecting systems

AU - Beattie, T.K.

AU - Tomlinson, A.

AU - Seal, D.

PY - 2002/11

Y1 - 2002/11

N2 - Hiti et al produced an interesting study investigating the susceptibility of three strains of Acanthamoeba to a PHMB (polyhexamethylene biguanide) based multipurpose solution (MPS), a one step peroxide system (3% H2O2), and a two step peroxide system (0.6% H2O2). However, no comment was made regarding the choice of strains tested, only one of which (A castellanii 4CL) was typical of those that cause keratitis in humans. Although testing of all three strains was of interest to the microbiologist, the only result that can be extrapolated to clinical practice and be of clinical relevance to the contact lens wearer is that for A castellanii (4CL).

AB - Hiti et al produced an interesting study investigating the susceptibility of three strains of Acanthamoeba to a PHMB (polyhexamethylene biguanide) based multipurpose solution (MPS), a one step peroxide system (3% H2O2), and a two step peroxide system (0.6% H2O2). However, no comment was made regarding the choice of strains tested, only one of which (A castellanii 4CL) was typical of those that cause keratitis in humans. Although testing of all three strains was of interest to the microbiologist, the only result that can be extrapolated to clinical practice and be of clinical relevance to the contact lens wearer is that for A castellanii (4CL).

KW - contact lens disinfecting systems

KW - Acanthamoeba

KW - A castellanii 4CL

UR - http://bjo.bmj.com/cgi/content/full/86/11/1319-b

M3 - Article

VL - 86

SP - 1310

EP - 1320

JO - British Journal of Ophthalmology

T2 - British Journal of Ophthalmology

JF - British Journal of Ophthalmology

SN - 0007-1161

IS - 11

ER -