Anatomical flow phantoms of the carotid bifurcation: potential application in training and assessment of endovascular device deployment

R.A. Black, D.M. Watts, S. Meagher, T.L. Poepping, R.H. Morgan, J. Wardlaw, M. Connell, C.J. Sutcliffe, P.R. Hoskins

    Research output: Contribution to journalArticle

    Abstract

    Doppler ultrasound is widely used in the diagnosis and monitoring of arterial disease. Current clinical measurement systems make use of continuous and pulsed ultrasound to measure blood flow velocity; however, the uncertainty associated with these measurements is great, which has serious implications for the screening of patients for treatment. Because local blood flow dynamics depend to a great extent on the geometry of the affected vessels, there is a need to develop anatomically accurate arterial flow phantoms with which to assess the accuracy of Doppler blood flow measurements made in diseased vessels. In this paper, we describe the computer-aided design and manufacturing (CAD-CAM) techniques that we used to fabricate anatomical flow phantoms based on images acquired by time-of-flight magnetic resonance imaging (TOF-MRI). Three-dimensional CAD models of the carotid bifurcation were generated from data acquired from sequential MRI slice scans, from which solid master patterns were made by means of stereolithography. Thereafter, an investment casting procedure was used to fabricate identical flow phantoms for use in parallel experiments involving both laser and Doppler ultrasound measurement techniques.
    LanguageEnglish
    Pages43-44
    Number of pages1
    JournalJournal of Cardiovascular Surgery
    Volume47
    Publication statusPublished - 2006

    Fingerprint

    Computer-Aided Design
    Doppler Ultrasonography
    Equipment and Supplies
    Magnetic Resonance Imaging
    Blood Flow Velocity
    Uncertainty
    Lasers
    Therapeutics

    Keywords

    • cardiovascular surgery
    • bioengineering
    • bifurcation

    Cite this

    Black, R.A. ; Watts, D.M. ; Meagher, S. ; Poepping, T.L. ; Morgan, R.H. ; Wardlaw, J. ; Connell, M. ; Sutcliffe, C.J. ; Hoskins, P.R. / Anatomical flow phantoms of the carotid bifurcation: potential application in training and assessment of endovascular device deployment. In: Journal of Cardiovascular Surgery. 2006 ; Vol. 47. pp. 43-44.
    @article{d045d2041fb64e3fa1e2f21ec07083b3,
    title = "Anatomical flow phantoms of the carotid bifurcation: potential application in training and assessment of endovascular device deployment",
    abstract = "Doppler ultrasound is widely used in the diagnosis and monitoring of arterial disease. Current clinical measurement systems make use of continuous and pulsed ultrasound to measure blood flow velocity; however, the uncertainty associated with these measurements is great, which has serious implications for the screening of patients for treatment. Because local blood flow dynamics depend to a great extent on the geometry of the affected vessels, there is a need to develop anatomically accurate arterial flow phantoms with which to assess the accuracy of Doppler blood flow measurements made in diseased vessels. In this paper, we describe the computer-aided design and manufacturing (CAD-CAM) techniques that we used to fabricate anatomical flow phantoms based on images acquired by time-of-flight magnetic resonance imaging (TOF-MRI). Three-dimensional CAD models of the carotid bifurcation were generated from data acquired from sequential MRI slice scans, from which solid master patterns were made by means of stereolithography. Thereafter, an investment casting procedure was used to fabricate identical flow phantoms for use in parallel experiments involving both laser and Doppler ultrasound measurement techniques.",
    keywords = "cardiovascular surgery, bioengineering, bifurcation",
    author = "R.A. Black and D.M. Watts and S. Meagher and T.L. Poepping and R.H. Morgan and J. Wardlaw and M. Connell and C.J. Sutcliffe and P.R. Hoskins",
    year = "2006",
    language = "English",
    volume = "47",
    pages = "43--44",
    journal = "Journal of Cardiovascular Surgery",
    issn = "1749-8090",

    }

    Black, RA, Watts, DM, Meagher, S, Poepping, TL, Morgan, RH, Wardlaw, J, Connell, M, Sutcliffe, CJ & Hoskins, PR 2006, 'Anatomical flow phantoms of the carotid bifurcation: potential application in training and assessment of endovascular device deployment' Journal of Cardiovascular Surgery, vol. 47, pp. 43-44.

    Anatomical flow phantoms of the carotid bifurcation: potential application in training and assessment of endovascular device deployment. / Black, R.A.; Watts, D.M.; Meagher, S.; Poepping, T.L.; Morgan, R.H.; Wardlaw, J.; Connell, M.; Sutcliffe, C.J.; Hoskins, P.R.

    In: Journal of Cardiovascular Surgery, Vol. 47, 2006, p. 43-44.

    Research output: Contribution to journalArticle

    TY - JOUR

    T1 - Anatomical flow phantoms of the carotid bifurcation: potential application in training and assessment of endovascular device deployment

    AU - Black, R.A.

    AU - Watts, D.M.

    AU - Meagher, S.

    AU - Poepping, T.L.

    AU - Morgan, R.H.

    AU - Wardlaw, J.

    AU - Connell, M.

    AU - Sutcliffe, C.J.

    AU - Hoskins, P.R.

    PY - 2006

    Y1 - 2006

    N2 - Doppler ultrasound is widely used in the diagnosis and monitoring of arterial disease. Current clinical measurement systems make use of continuous and pulsed ultrasound to measure blood flow velocity; however, the uncertainty associated with these measurements is great, which has serious implications for the screening of patients for treatment. Because local blood flow dynamics depend to a great extent on the geometry of the affected vessels, there is a need to develop anatomically accurate arterial flow phantoms with which to assess the accuracy of Doppler blood flow measurements made in diseased vessels. In this paper, we describe the computer-aided design and manufacturing (CAD-CAM) techniques that we used to fabricate anatomical flow phantoms based on images acquired by time-of-flight magnetic resonance imaging (TOF-MRI). Three-dimensional CAD models of the carotid bifurcation were generated from data acquired from sequential MRI slice scans, from which solid master patterns were made by means of stereolithography. Thereafter, an investment casting procedure was used to fabricate identical flow phantoms for use in parallel experiments involving both laser and Doppler ultrasound measurement techniques.

    AB - Doppler ultrasound is widely used in the diagnosis and monitoring of arterial disease. Current clinical measurement systems make use of continuous and pulsed ultrasound to measure blood flow velocity; however, the uncertainty associated with these measurements is great, which has serious implications for the screening of patients for treatment. Because local blood flow dynamics depend to a great extent on the geometry of the affected vessels, there is a need to develop anatomically accurate arterial flow phantoms with which to assess the accuracy of Doppler blood flow measurements made in diseased vessels. In this paper, we describe the computer-aided design and manufacturing (CAD-CAM) techniques that we used to fabricate anatomical flow phantoms based on images acquired by time-of-flight magnetic resonance imaging (TOF-MRI). Three-dimensional CAD models of the carotid bifurcation were generated from data acquired from sequential MRI slice scans, from which solid master patterns were made by means of stereolithography. Thereafter, an investment casting procedure was used to fabricate identical flow phantoms for use in parallel experiments involving both laser and Doppler ultrasound measurement techniques.

    KW - cardiovascular surgery

    KW - bioengineering

    KW - bifurcation

    UR - http://www.minervamedica.it/index2.t

    M3 - Article

    VL - 47

    SP - 43

    EP - 44

    JO - Journal of Cardiovascular Surgery

    T2 - Journal of Cardiovascular Surgery

    JF - Journal of Cardiovascular Surgery

    SN - 1749-8090

    ER -