Abstract

For analytical applications involving label free biosensors and multiple measurements, i.e. across an electrode array, it is essential to develop complete sensor systems capable of functionalisation and of producing highly consistent responses. To achieve this, a multi-microelectrode device bearing twenty-four equivalent 50 µm diameter Pt disc microelectrodes was designed in an integrated 3-electrode system configuration and then fabricated. Cyclic voltammetry and electrochemical impedance spectroscopy were used for initial electrochemical
characterisation of the individual working electrodes. These confirmed the expected consistency of performance with a high degree of measurement reproducibility for each microelectrode across the array. With the aim of assessing the potential for production of an enhanced multi-electrode sensor for biomedical use, the working electrodes were then functionalised with 6-mercapto-1-hexanol (MCH). This is a well-known and commonly employed surface modification process, which involves the same principles of thiol attachment chemistry and self-assembled monolayer (SAM) formation commonly employed in the functionalisation of electrodes and the formation of biosensors. Following this SAM formation, the reproducibility of the observed electrochemical
signal between electrodes was seen to decrease markedly, compromising the ability to achieve consistent analytical measurements from the sensor array following this relatively simple and well-established surface modification. To successfully and consistently functionalise the sensors it was necessary to dilute the constituent molecules by a factor of ten thousand to support adequate SAM
formation on microelectrodes. The use of this multi-electrode device therefore demonstrates in a high throughput manner irreproducibility in the SAM formation process at the higher concentration, even though these electrodes are apparently functionalised simultaneously in the same film formation environment, confirming that the often seen significant electrode-to-electrode variation in label-free SAM biosensing films formed under such conditions is not likely to be due to variation in film deposition conditions, but rather kinetically controlled variation in the SAM layer formation process at these microelectrodes.
LanguageEnglish
Pages1891-1902
Number of pages12
JournalSensors
Volume18
Issue number6
DOIs
Publication statusPublished - 9 Jun 2018

Fingerprint

Microelectrodes
Electrodes
electrodes
Self assembled monolayers
sensors
Biosensing Techniques
bioinstrumentation
Biosensors
Surface treatment
Labels
Sensors
6-mercapto-1-hexanol
Bearings (structural)
Dielectric Spectroscopy
Equipment and Supplies
Sensor arrays
Electrochemical impedance spectroscopy
Sulfhydryl Compounds
thiols
Cyclic voltammetry

Keywords

  • biosensor labelling
  • sensor systems
  • biosensing films

Cite this

Corrigan, Damion K. ; Vezza, Vincent ; Schulze, Holger ; Bachmann, Till T. ; Mount, Andrew R. ; Walton, Anthony J. ; Terry, Jonathan G. / A microelectrode array with reproducible performance shows loss of consistency following functionalization with a self-assembled 6-mercapto-1-hexanol layer. In: Sensors. 2018 ; Vol. 18, No. 6. pp. 1891-1902.
@article{ce3096254ee4478d9a4d2e4e470b5853,
title = "A microelectrode array with reproducible performance shows loss of consistency following functionalization with a self-assembled 6-mercapto-1-hexanol layer",
abstract = "For analytical applications involving label free biosensors and multiple measurements, i.e. across an electrode array, it is essential to develop complete sensor systems capable of functionalisation and of producing highly consistent responses. To achieve this, a multi-microelectrode device bearing twenty-four equivalent 50 µm diameter Pt disc microelectrodes was designed in an integrated 3-electrode system configuration and then fabricated. Cyclic voltammetry and electrochemical impedance spectroscopy were used for initial electrochemicalcharacterisation of the individual working electrodes. These confirmed the expected consistency of performance with a high degree of measurement reproducibility for each microelectrode across the array. With the aim of assessing the potential for production of an enhanced multi-electrode sensor for biomedical use, the working electrodes were then functionalised with 6-mercapto-1-hexanol (MCH). This is a well-known and commonly employed surface modification process, which involves the same principles of thiol attachment chemistry and self-assembled monolayer (SAM) formation commonly employed in the functionalisation of electrodes and the formation of biosensors. Following this SAM formation, the reproducibility of the observed electrochemicalsignal between electrodes was seen to decrease markedly, compromising the ability to achieve consistent analytical measurements from the sensor array following this relatively simple and well-established surface modification. To successfully and consistently functionalise the sensors it was necessary to dilute the constituent molecules by a factor of ten thousand to support adequate SAMformation on microelectrodes. The use of this multi-electrode device therefore demonstrates in a high throughput manner irreproducibility in the SAM formation process at the higher concentration, even though these electrodes are apparently functionalised simultaneously in the same film formation environment, confirming that the often seen significant electrode-to-electrode variation in label-free SAM biosensing films formed under such conditions is not likely to be due to variation in film deposition conditions, but rather kinetically controlled variation in the SAM layer formation process at these microelectrodes.",
keywords = "biosensor labelling, sensor systems, biosensing films",
author = "Corrigan, {Damion K.} and Vincent Vezza and Holger Schulze and Bachmann, {Till T.} and Mount, {Andrew R.} and Walton, {Anthony J.} and Terry, {Jonathan G.}",
year = "2018",
month = "6",
day = "9",
doi = "10.3390/s18061891",
language = "English",
volume = "18",
pages = "1891--1902",
journal = "Sensors",
issn = "1424-8220",
number = "6",

}

A microelectrode array with reproducible performance shows loss of consistency following functionalization with a self-assembled 6-mercapto-1-hexanol layer. / Corrigan, Damion K.; Vezza, Vincent; Schulze, Holger; Bachmann, Till T.; Mount, Andrew R.; Walton, Anthony J.; Terry, Jonathan G.

In: Sensors, Vol. 18, No. 6, 09.06.2018, p. 1891-1902.

Research output: Contribution to journalArticle

TY - JOUR

T1 - A microelectrode array with reproducible performance shows loss of consistency following functionalization with a self-assembled 6-mercapto-1-hexanol layer

AU - Corrigan, Damion K.

AU - Vezza, Vincent

AU - Schulze, Holger

AU - Bachmann, Till T.

AU - Mount, Andrew R.

AU - Walton, Anthony J.

AU - Terry, Jonathan G.

PY - 2018/6/9

Y1 - 2018/6/9

N2 - For analytical applications involving label free biosensors and multiple measurements, i.e. across an electrode array, it is essential to develop complete sensor systems capable of functionalisation and of producing highly consistent responses. To achieve this, a multi-microelectrode device bearing twenty-four equivalent 50 µm diameter Pt disc microelectrodes was designed in an integrated 3-electrode system configuration and then fabricated. Cyclic voltammetry and electrochemical impedance spectroscopy were used for initial electrochemicalcharacterisation of the individual working electrodes. These confirmed the expected consistency of performance with a high degree of measurement reproducibility for each microelectrode across the array. With the aim of assessing the potential for production of an enhanced multi-electrode sensor for biomedical use, the working electrodes were then functionalised with 6-mercapto-1-hexanol (MCH). This is a well-known and commonly employed surface modification process, which involves the same principles of thiol attachment chemistry and self-assembled monolayer (SAM) formation commonly employed in the functionalisation of electrodes and the formation of biosensors. Following this SAM formation, the reproducibility of the observed electrochemicalsignal between electrodes was seen to decrease markedly, compromising the ability to achieve consistent analytical measurements from the sensor array following this relatively simple and well-established surface modification. To successfully and consistently functionalise the sensors it was necessary to dilute the constituent molecules by a factor of ten thousand to support adequate SAMformation on microelectrodes. The use of this multi-electrode device therefore demonstrates in a high throughput manner irreproducibility in the SAM formation process at the higher concentration, even though these electrodes are apparently functionalised simultaneously in the same film formation environment, confirming that the often seen significant electrode-to-electrode variation in label-free SAM biosensing films formed under such conditions is not likely to be due to variation in film deposition conditions, but rather kinetically controlled variation in the SAM layer formation process at these microelectrodes.

AB - For analytical applications involving label free biosensors and multiple measurements, i.e. across an electrode array, it is essential to develop complete sensor systems capable of functionalisation and of producing highly consistent responses. To achieve this, a multi-microelectrode device bearing twenty-four equivalent 50 µm diameter Pt disc microelectrodes was designed in an integrated 3-electrode system configuration and then fabricated. Cyclic voltammetry and electrochemical impedance spectroscopy were used for initial electrochemicalcharacterisation of the individual working electrodes. These confirmed the expected consistency of performance with a high degree of measurement reproducibility for each microelectrode across the array. With the aim of assessing the potential for production of an enhanced multi-electrode sensor for biomedical use, the working electrodes were then functionalised with 6-mercapto-1-hexanol (MCH). This is a well-known and commonly employed surface modification process, which involves the same principles of thiol attachment chemistry and self-assembled monolayer (SAM) formation commonly employed in the functionalisation of electrodes and the formation of biosensors. Following this SAM formation, the reproducibility of the observed electrochemicalsignal between electrodes was seen to decrease markedly, compromising the ability to achieve consistent analytical measurements from the sensor array following this relatively simple and well-established surface modification. To successfully and consistently functionalise the sensors it was necessary to dilute the constituent molecules by a factor of ten thousand to support adequate SAMformation on microelectrodes. The use of this multi-electrode device therefore demonstrates in a high throughput manner irreproducibility in the SAM formation process at the higher concentration, even though these electrodes are apparently functionalised simultaneously in the same film formation environment, confirming that the often seen significant electrode-to-electrode variation in label-free SAM biosensing films formed under such conditions is not likely to be due to variation in film deposition conditions, but rather kinetically controlled variation in the SAM layer formation process at these microelectrodes.

KW - biosensor labelling

KW - sensor systems

KW - biosensing films

UR - http://www.mdpi.com/journal/sensors

U2 - 10.3390/s18061891

DO - 10.3390/s18061891

M3 - Article

VL - 18

SP - 1891

EP - 1902

JO - Sensors

T2 - Sensors

JF - Sensors

SN - 1424-8220

IS - 6

ER -