A method of normalizing cathodoluminescence images of electron transparent foils for thickness contrast applied to InGaN quantum wells

N.M. Boyall, K. Durose, I.M. Watson

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

The uniformity of panchromatic cathodoluminescence (CL) from In0.09Ga0.91N/GaN quantum wells at 100 K was investigated using a combined transmission electron microscope-cathodoluminescence instrument. A technique for correcting CL images of electron-transparent wedge specimens for thickness contrast artefacts is presented. The foil thickness was estimated using the dynamical formulation of the relationship between the thickness and the (experimentally observed) transmitted electron intensity. For a given thickness the CL intensity was calculated using the Everhart-Hoff depth-dose function and also taking into account surface recombination losses. Experimental CL images were normalized by dividing by the calculated CL value at each point. The procedure was successful in calculating the underlying materials contrast in CL images of thin specimens of InGaN single quantum wells. Non-uniformities in the CL emission on the scale of similar to0.7 mum were observed.
LanguageEnglish
Pages41-46
Number of pages5
JournalJournal of Microscopy
Volume209
Issue number1
DOIs
Publication statusPublished - Jan 2003

Fingerprint

Electrons
Artifacts
Contrast Media
Genetic Recombination

Keywords

  • cathodoluminescence
  • InGaN quantum wells
  • thickness normalization
  • transmission electron microscopy

Cite this

@article{fef280600c3b44c1adea01af2b51ca45,
title = "A method of normalizing cathodoluminescence images of electron transparent foils for thickness contrast applied to InGaN quantum wells",
abstract = "The uniformity of panchromatic cathodoluminescence (CL) from In0.09Ga0.91N/GaN quantum wells at 100 K was investigated using a combined transmission electron microscope-cathodoluminescence instrument. A technique for correcting CL images of electron-transparent wedge specimens for thickness contrast artefacts is presented. The foil thickness was estimated using the dynamical formulation of the relationship between the thickness and the (experimentally observed) transmitted electron intensity. For a given thickness the CL intensity was calculated using the Everhart-Hoff depth-dose function and also taking into account surface recombination losses. Experimental CL images were normalized by dividing by the calculated CL value at each point. The procedure was successful in calculating the underlying materials contrast in CL images of thin specimens of InGaN single quantum wells. Non-uniformities in the CL emission on the scale of similar to0.7 mum were observed.",
keywords = "cathodoluminescence, InGaN quantum wells, thickness normalization, transmission electron microscopy",
author = "N.M. Boyall and K. Durose and I.M. Watson",
year = "2003",
month = "1",
doi = "10.1046/j.1365-2818.2003.01099.x",
language = "English",
volume = "209",
pages = "41--46",
journal = "Journal of Microscopy",
issn = "0022-2720",
number = "1",

}

A method of normalizing cathodoluminescence images of electron transparent foils for thickness contrast applied to InGaN quantum wells. / Boyall, N.M.; Durose, K.; Watson, I.M.

In: Journal of Microscopy, Vol. 209, No. 1, 01.2003, p. 41-46.

Research output: Contribution to journalArticle

TY - JOUR

T1 - A method of normalizing cathodoluminescence images of electron transparent foils for thickness contrast applied to InGaN quantum wells

AU - Boyall, N.M.

AU - Durose, K.

AU - Watson, I.M.

PY - 2003/1

Y1 - 2003/1

N2 - The uniformity of panchromatic cathodoluminescence (CL) from In0.09Ga0.91N/GaN quantum wells at 100 K was investigated using a combined transmission electron microscope-cathodoluminescence instrument. A technique for correcting CL images of electron-transparent wedge specimens for thickness contrast artefacts is presented. The foil thickness was estimated using the dynamical formulation of the relationship between the thickness and the (experimentally observed) transmitted electron intensity. For a given thickness the CL intensity was calculated using the Everhart-Hoff depth-dose function and also taking into account surface recombination losses. Experimental CL images were normalized by dividing by the calculated CL value at each point. The procedure was successful in calculating the underlying materials contrast in CL images of thin specimens of InGaN single quantum wells. Non-uniformities in the CL emission on the scale of similar to0.7 mum were observed.

AB - The uniformity of panchromatic cathodoluminescence (CL) from In0.09Ga0.91N/GaN quantum wells at 100 K was investigated using a combined transmission electron microscope-cathodoluminescence instrument. A technique for correcting CL images of electron-transparent wedge specimens for thickness contrast artefacts is presented. The foil thickness was estimated using the dynamical formulation of the relationship between the thickness and the (experimentally observed) transmitted electron intensity. For a given thickness the CL intensity was calculated using the Everhart-Hoff depth-dose function and also taking into account surface recombination losses. Experimental CL images were normalized by dividing by the calculated CL value at each point. The procedure was successful in calculating the underlying materials contrast in CL images of thin specimens of InGaN single quantum wells. Non-uniformities in the CL emission on the scale of similar to0.7 mum were observed.

KW - cathodoluminescence

KW - InGaN quantum wells

KW - thickness normalization

KW - transmission electron microscopy

U2 - 10.1046/j.1365-2818.2003.01099.x

DO - 10.1046/j.1365-2818.2003.01099.x

M3 - Article

VL - 209

SP - 41

EP - 46

JO - Journal of Microscopy

T2 - Journal of Microscopy

JF - Journal of Microscopy

SN - 0022-2720

IS - 1

ER -