A highly compact packaging concept for ultrasound transducer arrays embedded in neurosurgical needles’

Giuseppe Schiavone, Thomas Jones, Dennis Price, Rachael McPhillips, Yun Jiang, Zhen Qiu, Carl Meggs, syed O. Mahboob, Sam Eljamel, Tim W. Button, christine E.M Demore, Sandy Cochran, Marc P.Y Desmulliez

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

State-of-the-art neurosurgery intervention relies heavily on information from tissue imaging taken at a pre-operative stage. However, the data retrieved prior to performing an opening in the patient’s skull may present inconsistencies with respect to the tissue position observed by the surgeon during intervention, due to both the pulsing vasculature and possible displacements of the brain. The consequent uncertainty of the actual tissue position during the insertion of surgical tools has resulted in great interest in real-time guidance techniques. Ultrasound guidance during neurosurgery is a promising method for imaging the tissue while inserting surgical tools, as it may provide high resolution images. Microfabrication techniques have enabled the miniaturisation of ultrasound arrays to fit needle gauges below 2 mm inner diameter. However, the integration of array transducers in surgical needles requires the development of advanced interconnection techniques that can provide an interface between the microscale array elements and the macroscale connectors to the driving electronics. This paper presents progress towards a novel packaging scheme that uses a thin flexible printed circuit board (PCB) wound inside a surgical needle. The flexible PCB is connected to a probe at the tip of the needle by means of magnetically aligned anisotropic conductive paste. This bonding technology offers higher compactness compared to conventional wire bonding, as the individual electrical connections are isolated from one another within the volume of the paste line, and applies a reduced thermal load compared to thermo-compression or eutectic packaging techniques. The reduction in the volume required for the interconnection allows for denser wiring of ultrasound probes within interventional tools. This allows the integration of arrays with higher element counts in confined packages, potentially enabling multi-modality imaging with Raman, OCT, and impediography. Promising experimental results and a prototype needle assembly are presented to demonstrate the viability of the proposed packaging scheme. The progress reported in this work are steps towards the production of fully-functional imaging-enabled needles that can be used as surgical guidance tools.
LanguageEnglish
Pages1-11
Number of pages11
JournalMicrosystem Technologies
DOIs
Publication statusPublished - 18 Jan 2016

Fingerprint

packaging
needles
Needles
Transducers
Packaging
transducers
Ultrasonics
Tissue
Neurosurgery
Imaging techniques
printed circuits
circuit boards
Ointments
Printed circuit boards
surgeons
skull
Adhesive pastes
wiring
probes
Microfabrication

Keywords

  • tissue imaging
  • ultrasound
  • neurosurgical needles

Cite this

Schiavone, Giuseppe ; Jones, Thomas ; Price, Dennis ; McPhillips, Rachael ; Jiang, Yun ; Qiu, Zhen ; Meggs, Carl ; Mahboob, syed O. ; Eljamel, Sam ; Button, Tim W. ; Demore, christine E.M ; Cochran, Sandy ; Desmulliez, Marc P.Y. / A highly compact packaging concept for ultrasound transducer arrays embedded in neurosurgical needles’. In: Microsystem Technologies. 2016 ; pp. 1-11.
@article{c50c5e3e27794b029993fe5b9d459dc3,
title = "A highly compact packaging concept for ultrasound transducer arrays embedded in neurosurgical needles’",
abstract = "State-of-the-art neurosurgery intervention relies heavily on information from tissue imaging taken at a pre-operative stage. However, the data retrieved prior to performing an opening in the patient’s skull may present inconsistencies with respect to the tissue position observed by the surgeon during intervention, due to both the pulsing vasculature and possible displacements of the brain. The consequent uncertainty of the actual tissue position during the insertion of surgical tools has resulted in great interest in real-time guidance techniques. Ultrasound guidance during neurosurgery is a promising method for imaging the tissue while inserting surgical tools, as it may provide high resolution images. Microfabrication techniques have enabled the miniaturisation of ultrasound arrays to fit needle gauges below 2 mm inner diameter. However, the integration of array transducers in surgical needles requires the development of advanced interconnection techniques that can provide an interface between the microscale array elements and the macroscale connectors to the driving electronics. This paper presents progress towards a novel packaging scheme that uses a thin flexible printed circuit board (PCB) wound inside a surgical needle. The flexible PCB is connected to a probe at the tip of the needle by means of magnetically aligned anisotropic conductive paste. This bonding technology offers higher compactness compared to conventional wire bonding, as the individual electrical connections are isolated from one another within the volume of the paste line, and applies a reduced thermal load compared to thermo-compression or eutectic packaging techniques. The reduction in the volume required for the interconnection allows for denser wiring of ultrasound probes within interventional tools. This allows the integration of arrays with higher element counts in confined packages, potentially enabling multi-modality imaging with Raman, OCT, and impediography. Promising experimental results and a prototype needle assembly are presented to demonstrate the viability of the proposed packaging scheme. The progress reported in this work are steps towards the production of fully-functional imaging-enabled needles that can be used as surgical guidance tools.",
keywords = "tissue imaging, ultrasound, neurosurgical needles",
author = "Giuseppe Schiavone and Thomas Jones and Dennis Price and Rachael McPhillips and Yun Jiang and Zhen Qiu and Carl Meggs and Mahboob, {syed O.} and Sam Eljamel and Button, {Tim W.} and Demore, {christine E.M} and Sandy Cochran and Desmulliez, {Marc P.Y}",
year = "2016",
month = "1",
day = "18",
doi = "10.1007/s00542-015-2775-1",
language = "English",
pages = "1--11",
journal = "Microsystem Technologies",
issn = "0946-7076",
publisher = "Springer-Verlag",

}

Schiavone, G, Jones, T, Price, D, McPhillips, R, Jiang, Y, Qiu, Z, Meggs, C, Mahboob, SO, Eljamel, S, Button, TW, Demore, CEM, Cochran, S & Desmulliez, MPY 2016, 'A highly compact packaging concept for ultrasound transducer arrays embedded in neurosurgical needles’' Microsystem Technologies, pp. 1-11. https://doi.org/10.1007/s00542-015-2775-1

A highly compact packaging concept for ultrasound transducer arrays embedded in neurosurgical needles’. / Schiavone, Giuseppe; Jones, Thomas; Price, Dennis; McPhillips, Rachael; Jiang, Yun; Qiu, Zhen; Meggs, Carl; Mahboob, syed O.; Eljamel, Sam; Button, Tim W.; Demore, christine E.M; Cochran, Sandy; Desmulliez, Marc P.Y.

In: Microsystem Technologies, 18.01.2016, p. 1-11.

Research output: Contribution to journalArticle

TY - JOUR

T1 - A highly compact packaging concept for ultrasound transducer arrays embedded in neurosurgical needles’

AU - Schiavone, Giuseppe

AU - Jones, Thomas

AU - Price, Dennis

AU - McPhillips, Rachael

AU - Jiang, Yun

AU - Qiu, Zhen

AU - Meggs, Carl

AU - Mahboob, syed O.

AU - Eljamel, Sam

AU - Button, Tim W.

AU - Demore, christine E.M

AU - Cochran, Sandy

AU - Desmulliez, Marc P.Y

PY - 2016/1/18

Y1 - 2016/1/18

N2 - State-of-the-art neurosurgery intervention relies heavily on information from tissue imaging taken at a pre-operative stage. However, the data retrieved prior to performing an opening in the patient’s skull may present inconsistencies with respect to the tissue position observed by the surgeon during intervention, due to both the pulsing vasculature and possible displacements of the brain. The consequent uncertainty of the actual tissue position during the insertion of surgical tools has resulted in great interest in real-time guidance techniques. Ultrasound guidance during neurosurgery is a promising method for imaging the tissue while inserting surgical tools, as it may provide high resolution images. Microfabrication techniques have enabled the miniaturisation of ultrasound arrays to fit needle gauges below 2 mm inner diameter. However, the integration of array transducers in surgical needles requires the development of advanced interconnection techniques that can provide an interface between the microscale array elements and the macroscale connectors to the driving electronics. This paper presents progress towards a novel packaging scheme that uses a thin flexible printed circuit board (PCB) wound inside a surgical needle. The flexible PCB is connected to a probe at the tip of the needle by means of magnetically aligned anisotropic conductive paste. This bonding technology offers higher compactness compared to conventional wire bonding, as the individual electrical connections are isolated from one another within the volume of the paste line, and applies a reduced thermal load compared to thermo-compression or eutectic packaging techniques. The reduction in the volume required for the interconnection allows for denser wiring of ultrasound probes within interventional tools. This allows the integration of arrays with higher element counts in confined packages, potentially enabling multi-modality imaging with Raman, OCT, and impediography. Promising experimental results and a prototype needle assembly are presented to demonstrate the viability of the proposed packaging scheme. The progress reported in this work are steps towards the production of fully-functional imaging-enabled needles that can be used as surgical guidance tools.

AB - State-of-the-art neurosurgery intervention relies heavily on information from tissue imaging taken at a pre-operative stage. However, the data retrieved prior to performing an opening in the patient’s skull may present inconsistencies with respect to the tissue position observed by the surgeon during intervention, due to both the pulsing vasculature and possible displacements of the brain. The consequent uncertainty of the actual tissue position during the insertion of surgical tools has resulted in great interest in real-time guidance techniques. Ultrasound guidance during neurosurgery is a promising method for imaging the tissue while inserting surgical tools, as it may provide high resolution images. Microfabrication techniques have enabled the miniaturisation of ultrasound arrays to fit needle gauges below 2 mm inner diameter. However, the integration of array transducers in surgical needles requires the development of advanced interconnection techniques that can provide an interface between the microscale array elements and the macroscale connectors to the driving electronics. This paper presents progress towards a novel packaging scheme that uses a thin flexible printed circuit board (PCB) wound inside a surgical needle. The flexible PCB is connected to a probe at the tip of the needle by means of magnetically aligned anisotropic conductive paste. This bonding technology offers higher compactness compared to conventional wire bonding, as the individual electrical connections are isolated from one another within the volume of the paste line, and applies a reduced thermal load compared to thermo-compression or eutectic packaging techniques. The reduction in the volume required for the interconnection allows for denser wiring of ultrasound probes within interventional tools. This allows the integration of arrays with higher element counts in confined packages, potentially enabling multi-modality imaging with Raman, OCT, and impediography. Promising experimental results and a prototype needle assembly are presented to demonstrate the viability of the proposed packaging scheme. The progress reported in this work are steps towards the production of fully-functional imaging-enabled needles that can be used as surgical guidance tools.

KW - tissue imaging

KW - ultrasound

KW - neurosurgical needles

U2 - 10.1007/s00542-015-2775-1

DO - 10.1007/s00542-015-2775-1

M3 - Article

SP - 1

EP - 11

JO - Microsystem Technologies

T2 - Microsystem Technologies

JF - Microsystem Technologies

SN - 0946-7076

ER -