• United Kingdom

Accepting PhD Students

Willing to speak to media

20092022
If you made any changes in Pure these will be visible here soon.

Research Output 2009 2019

  • 25 Article
  • 1 Conference contribution book
  • 1 Review article
  • 1 Patent
2019
5 Citations (Scopus)

A review of microfabricated electrochemical biosensors for DNA detection

Blair, E. O. & Corrigan, D. K., 1 Jun 2019, In : Biosensors and Bioelectronics. 134, p. 57-67 11 p.

Research output: Contribution to journalReview article

Biosensing Techniques
Biosensors
DNA
Point-of-Care Systems
Microtechnology
6 Citations (Scopus)

Development of a needle shaped microelectrode for electrochemical detection of the sepsis biomarker interleukin-6 (IL-6) in real time

Russell, C., Ward, A. C., Vezza, V., Hoskisson, P., Alcorn, D., Steenson, D. P. & Corrigan, D. K., 1 Feb 2019, In : Biosensors and Bioelectronics. 126, p. 806-814 9 p.

Research output: Contribution to journalArticle

Open Access
File
Microelectrodes
Biomarkers
Needles
Interleukin-6
Sepsis
oxacillin
Oxacillin
sensors (equipment)
Electrodes
Tetracycline Resistance
Antibiotics
Electrodes
Anti-Bacterial Agents
Costs and Cost Analysis
Testing
2 Citations (Scopus)

SAM composition and electrode roughness affect performance of a DNA biosensor for antibiotic resistance

Butterworth, A., Blues, E., Williamson, P., Cardona, M. J., Gray, L. & Corrigan, D. K., 7 Feb 2019, In : Biosensors. 9, 1, 12 p., 22.

Research output: Contribution to journalArticle

Open Access
File
Biosensing Techniques
Self assembled monolayers
Antibiotics
Microbial Drug Resistance
Biosensors
2018
1 Citation (Scopus)

A microelectrode array with reproducible performance shows loss of consistency following functionalization with a self-assembled 6-mercapto-1-hexanol layer

Corrigan, D. K., Vezza, V., Schulze, H., Bachmann, T. T., Mount, A. R., Walton, A. J. & Terry, J. G., 9 Jun 2018, In : Sensors. 18, 6, p. 1891-1902 12 p.

Research output: Contribution to journalArticle

Open Access
File
Microelectrodes
Electrodes
electrodes
Self assembled monolayers
sensors
2017
5 Citations (Scopus)

Impedimetric measurement of DNA-DNA hybridisation using microelectrodes with different radii for detection of methicillin resistant Staphylococcus aureus (MRSA)

Quan Li, P., Piper, A., Schmueser, I., Mount, A. R. & Corrigan, D. K., 7 Jun 2017, In : Analyst. 142, 11, p. 1946-1952 7 p.

Research output: Contribution to journalArticle

Open Access
File
Methicillin
Microelectrodes
Methicillin-Resistant Staphylococcus aureus
Electrodes
electrode
4 Citations (Scopus)
Open Access
File
DNA sequences
Assays
DNA
Electrochemical impedance spectroscopy
Oligonucleotides
2 Citations (Scopus)

Improving the yield and lifetime of microfabricated sensors for harsh environments

Blair, E., Corrigan, D. K., Levene, H. J., Schmueser, I., Terry, J. G., Smith, S., Mount, A. R. & Walton, A. J., 31 Aug 2017, In : IEEE Transactions on Semiconductor Manufacturing. 30, 3, p. 192-200 9 p.

Research output: Contribution to journalArticle

Open Access
File
high temperature environments
life (durability)
Caustics
Electrodes
electrodes

Towards simple, rapid point of care testing for clinically important protein biomarkers of sepsis

Steel, L., Ward, A. C., Jeffrey, C., Alcorn, D. & Corrigan, D. K., 15 Dec 2017, In : SCIOL Biotechnology. 1, 1, p. 1-8

Research output: Contribution to journalArticle

Open Access
File
Biomarkers
Sepsis
Proteins
Testing
Assays
2016
8 Citations (Scopus)

Advances in electroanalysis, sensing and monitoring in molten salts

Corrigan, D. K., Elliott, J. P., Blair, E. O., Reeves, S. J., Schmüser, I., Walton, A. J. & Mount, A. R., 2 Jun 2016, In : Faraday Discussions. 190, p. 351-366 16 p.

Research output: Contribution to journalArticle

Open Access
File
molten salts
Molten materials
Microelectrodes
Salts
Monitoring
14 Citations (Scopus)

Label- and amplification-free electrochemical detection of bacterial ribosomal RNA

Henihan, G., Schulze, H., Corrigan, D. K., Giraud, G., Terry, J. G., Hardie, A., Campbell, C. J., Walton, A. J., Crain, J., Pethig, R., Templeton, K. E., Mount, A. R. & Bachmann, T. T., 15 Jul 2016, In : Biosensors and Bioelectronics. 81, p. 487-494 8 p.

Research output: Contribution to journalArticle

Open Access
File
Bacterial RNA
Ribosomal RNA
Point-of-Care Systems
Amplification
Labels
2 Citations (Scopus)

Test structures to support the development and process verification of microelectrodes for high temperature operation in molten salts

Blair, E. O., Corrigan, D. K., Schmueser, I., Terry, J. G., Smith, S., Mount, A. R. & Walton, A. J., 23 May 2016, 29th IEEE ICMTS Conference Proceedings: March 28-31, Mielparque Yokohama, Japan. Piscataway, NJ.: IEEE, p. 158-162 5 p. 7476198

Research output: Chapter in Book/Report/Conference proceedingConference contribution book

High temperature operations
Microelectrodes
Molten materials
Salts
Fabrication
2015
9 Citations (Scopus)

Development and optimization of durable microelectrodes for quantitative electroanalysis in molten salt

Blair, E. O., Corrigan, D. K., Terry, J. G., Mount, A. R. & Walton, A. J., 31 Oct 2015, In : Journal of Microelectromechanical Systems. 24, 5, p. 1346-1354 9 p.

Research output: Contribution to journalArticle

Open Access
File
Microelectrodes
Molten materials
Salts
Electrodes
Silicon wafers
2014
13 Citations (Scopus)

Enhanced electroanalysis in lithium potassium eutectic (LKE) using microfabricated square microelectrodes

Corrigan, D. K., Blair, E. O., Terry, J. G., Walton, A. J. & Mount, A. R., 18 Nov 2014, In : Analytical Chemistry. 86, 22, p. 11342-11348 7 p.

Research output: Contribution to journalArticle

Microelectrodes
Lithium
Eutectics
Molten materials
Potassium
10 Citations (Scopus)

Improving electrochemical biosensor performance by understanding the influence of target DNA length on assay sensitivity

Corrigan, D. K., Schulze, H., McDermott, R. A., Schmüser, I., Henihan, G., Henry, J. B., Bachmann, T. T. & Mount, A. R., 15 Oct 2014, In : Journal of Electroanalytical Chemistry. 732, p. 25-29 5 p.

Research output: Contribution to journalArticle

Biosensors
Electrochemical impedance spectroscopy
Assays
DNA
Nucleotides
2013
18 Citations (Scopus)

Development of a PCR-free electrochemical point of care test for clinical detection of methicillin resistant Staphylococcus aureus (MRSA)

Corrigan, D. K., Schulze, H., Henihan, G., Hardie, A., Ciani, I., Giraud, G., Terry, J. G., Walton, A. J., Pethig, R., Ghazal, P., Crain, J., Campbell, C. J., Templeton, K. E., Mount, A. R. & Bachmann, T. T., 21 Nov 2013, In : Analyst. 138, 22, p. 6997-7005 9 p.

Research output: Contribution to journalArticle

Point-of-Care Systems
Methicillin
Methicillin-Resistant Staphylococcus aureus
Assays
Electrodes
10 Citations (Scopus)

Nanoscale electrode arrays produced with microscale lithographic techniques for use in biomedical sensing applications

Terry, J. G., Schmüser, I., Underwood, I., Corrigan, D. K., Freeman, N. J., Bunting, A. S., Mount, A. R. & Walton, A. J., 2013, In : IET Nanobiotechnology. 7, 4, p. 125-134 10 p.

Research output: Contribution to journalArticle

Electrodes
Oxidation-Reduction
Microtechnology
Vertical Dimension
Redox reactions
2012

Detecting analytes

Corrigan, D., Bachmann, T. & Schulze, H., 21 Dec 2012, Patent No. WO/2013/076143 , Priority date 22 Nov 2011

Research output: Patent

Nucleic acids
Assays
Patents and inventions
Pathogens
Electrochemical impedance spectroscopy
54 Citations (Scopus)

Development of immunosensors for direct detection of three wound infection biomarkers at point of care using electrochemical impedance spectroscopy

Ciani, I., Schulze, H., Corrigan, D. K., Henihan, G., Giraud, G., Terry, J. G., Walton, A. J., Pethig, R., Ghazal, P., Crain, J., Campbell, C. J., Bachmann, T. T. & Mount, A. R., 15 Jan 2012, In : Biosensors and Bioelectronics. 31, 1, p. 413-418 6 p.

Research output: Contribution to journalArticle

Point-of-Care Systems
Dielectric Spectroscopy
Immunosensors
Metalloproteases
Biomarkers
30 Citations (Scopus)

Impedimetric detection of single-stranded PCR products derived from methicillin resistant Staphylococcus aureus (MRSA) isolates

Corrigan, D. K., Schulze, H., Henihan, G., Ciani, I., Giraud, G., Terry, J. G., Walton, A. J., Pethig, R., Ghazal, P., Crain, J., Campbell, C. J., Mount, A. R. & Bachmann, T. T., 15 Apr 2012, In : Biosensors and Bioelectronics. 34, 1, p. 178-184 7 p.

Research output: Contribution to journalArticle

Dielectric Spectroscopy
Methicillin
Methicillin-Resistant Staphylococcus aureus
Electrodes
Point-of-Care Systems
3 Citations (Scopus)

Robust microelectrodes in molten salt analysis

Relf, A., Corrigan, D., Brady, C. L., Terry, J. G., Walton, A. J. & Mount, A. R., 4 Jun 2012, In : ECS Transactions. 50, 11, p. 105-109 5 p.

Research output: Contribution to journalArticle

Microelectrodes
Molten materials
Salts
Photolithography
Plating
2011
29 Citations (Scopus)

Dielectrophoretic manipulation of ribosomal RNA

Giraud, G., Pethig, R., Schulze, H., Henihan, G., Terry, J. G., Menachery, A., Ciani, I., Corrigan, D., Campbell, C. J., Mount, A. R., Ghazal, P., Walton, A. J., Crain, J. & Bachmann, T. T., 28 Jun 2011, In : Biomicrofluidics. 5, 2, 16 p., 024116.

Research output: Contribution to journalArticle

ribonucleic acids
Ribosomal RNA
Electrophoresis
manipulators
Molecules
2010
16 Citations (Scopus)

Analysis of short tandem repeats by using SERS monitoring and electrochemical melting

Corrigan, D. K., Gale, N., Brown, T. & Bartlett, P. N., 9 Aug 2010, In : Angewandte Chemie International Edition. 49, 34, p. 5917-5920 4 p.

Research output: Contribution to journalArticle

Tandem Repeat Sequences
DNA sequences
Microsatellite Repeats
Freezing
Electrodes
11 Citations (Scopus)

Towards the development of a rapid, portable, surface enhanced Raman spectroscopy based cleaning verification system for the drug nelarabine

Corrigan, D. K., Salton, N. A., Preston, C. & Piletsky, S., 2010, In : Journal of Pharmacy and Pharmacology. 62, 9, p. 1195-1200 6 p.

Research output: Contribution to journalArticle

Raman Spectrum Analysis
Pharmaceutical Preparations
High Pressure Liquid Chromatography
nelarabine
Drug Industry
2009
6 Citations (Scopus)

Application of surface-enhanced Raman spectroscopy (SERS) for cleaning verification in pharmaceutical manufacture

Corrigan, D. K., Cauchi, M., Piletsky, S. & Mccrossen, S., 30 Nov 2009, In : PDA Journal of Pharmaceutical Science and Technology. 63, 6, p. 568-574 7 p.

Research output: Contribution to journalArticle

Raman Spectrum Analysis
Drug products
Raman spectroscopy
Cleaning
Pharmaceutical Preparations
Diclofenac
Niacin
Steel
Acetaminophen
Ethanol
9 Citations (Scopus)
Ethyl Methanesulfonate
Alkylating Agents
Alkylation
Pharmaceutical Preparations
Coloring Agents