LEMKE: Partial Discharge Measurements

  • Euan Morris (Creator)

Dataset

Description

The LEMKE Partial Discharge Measurements dataset includes ASCII file outputs from PD testing of low density polyethylene (LDPE) and polypropylene film samples using a LEMKE LDS-6 measurement system.

Files include PD magnitude, phase, and period number (please note voltage measurements are not valid, the correct applied RMS voltage is in the file name).
For DC files the the phase measurement and period number allow for the calculation of time and time between pulses.

This work has been carried out through the EPSRC Centre for Doctoral Training in Future Power Networks and Smart Grids, run jointly between the University of Strathclyde and Imperial College London, grant number EP/L015471/1

Data embargo until 28/01/2018
Date made available28 Jul 2017
PublisherUniversity of Strathclyde
Temporal coverage6 Mar 2017 - 13 Jun 2017

Cite this